Ariston 41-116-04 installation instructions General Instructions

Page 3

1.1

GENERAL INSTRUCTIONS

Read the instructions and recommendations in these Installation Instructions

 

 

carefully to ensure proper installation, use and maintenance of the appliance.

Keep this manual in a safe place. You may need it for your own reference while our

Servicing Centre technicians or your installer may need to consult it in the future.

This is an appliance for the production of central heating (C.H.).

This appliance must be used only for the purpose for which it is designed.

The manufacturer declines all liability for damage caused by improper or negligent use.

No asbestos or other hazardous materials have been used in the fabrication of this product.

Before connecting the appliance, check that the information shown on the data plate and the table in section 7 comply with the electric, water and gas mains of the property. You will find the data plate on the reverse of the control panel.

The gas with which this appliance operates is also shown on the label at the bottom of the boiler.

Do not install this appliance in a damp environment or close to equipment which spray water or other liquids.

Do not place objects on the appliance.

Do not allow children or inexperienced persons to use the appliance without supervision.

If you smell gas in the room, do not turn on light switches, use the telephone or any other object which might cause sparks.

Open doors and windows immediately to ventilate the room.

Shut the gas mains tap (at or adjacent to the gas meter) or the valve of the gas cylinder and call your Gas Supplier immediately.

If you are going away for a long period of time, remember to shut the mains gas tap or the gas cylinder valve.

Always disconnect the appliance either by unplugging it from the mains or turning off the mains switch before cleaning the appliance or carrying out maintenance.

In the case of faults or failure, switch off the appliance and turn off the gas tap. Do not tamper with the appliance.

For repairs, call your local Authorised Servicing Centre and request the use of original spare parts. For in-guarantee repairs contact MTS (GB) Limited.

Check the following at least once a year:

1 - Check the seals for the water connections; replace any faulty seals.

2 - Check the gas seals; replace any faulty gas seals.

3 - Visual check of the entire unit.

4 - Visual check of the combustion process or analysis of combustion by-products (see section 4.5) and cleaning of the burner if needed.

5 - If called for by point. 3, dismantling and cleaning of the combustion chamber.

6 - If called for by point. 4, dismantling and cleaning of the burner jets.

7 - Visual check of the primary heat exchanger:

-check for overheating in the blade assembly;

-clean the exhaust fan if needed.

8 - Adjustment of the flow rate of the gas: flow rate for lighting, partial load and full load.

9 - Check of the heating safety systems:

-safety device for maximum temperature (overheat thermostat);

-safety device for maximum pressure (safety valve).

10- Check of the gas safety systems:

-safety device for lack of gas or flame ionisation (detection electrode);

-safety device for gas cock.

11- Check of the electrical connection (make sure it complies with the instructions in the manual).

12- General check of the combustion by-products of the discharge/ventilation system.

13- Check of the general performance of the unit.

3

Image 3 Contents
Installation Instructions Type C Boilers Table of Contents General Instructions Installation Overall ViewReference Standards Mounting the Appliance Electrical Connection Overall DimensionsSiting the Appliance ClearancesWater Connections GAS ConnectionResidual Head of the Boiler Tower Flue Components Flue ConnectionsRoom Thermostat Connection RffiOn/Off Switch Electrical DiagramGAS and Water Circuits H.W. Storage Cylinder 2 Port and 3 Port Valve InstallationsModel Commissioning Domestic HOT Water Priority KITInitial Preparation Removing the Front Panel Control PanelFume Discharge Monitoring Initial START-UP Combustion AnalysisBoiler Safety Systems Draining the System GAS Adjustments RffiChanging the Type of GAS Maintenance Number 41-116-04 Technical InformationServicing Instructions Type C Boilers Fault Finding Removing the front panel Replacement of PartsTo Gain General Access Servicing InstructionsRemoving the side panels Removing the sealed chamber front coverRemoving the electrodes Access to the Combustion ChamberRemoving the combustion cover Removing the burner and jetsRemoving the main heat exchanger Removing the fan Removing the air pressure switchServicing and Removal of the GAS Valve Setting the gas pressuresRffi Removing the gas valve Removing the spark generatorRemoving the automatic air vent 1. Unscrew valve top Z FIG Removing the pump pressure switchRemoving the safety valve Access to the Water CircuitRemoving the pump Removing the expansion vessel Removing the pressure gaugeRemoving the overheat thermostat Removing the frost thermostatRemoving the regulation thermostat Access to the Control System Checking the fuseRemoving the P.C.B.s Fault Finding Fault Finding GuideFlow -CHARTS YES Mbar Electrical DiagramsSF008A MicroSYSTEM 10 Rffi Ariston B063 Technical Service Hot Line 01494 23 99 84 1582