Ariston 41-116-04 installation instructions Rffi, Room Thermostat Connection

Page 9

COAXIAL SYSTEMS

FIG. 2.9

IMPORTANT!

For all flue systems, a restrictor must always be inserted into the boiler’s flue connector; the restrictor must be

Ø44 in diameter depending on the length of piping indicated in TABLE 2.1.

FIG 2.9 and FIG 2.10 illustrate some of the various designs for coaxial or twin pipe flue systems.

For fur ther information on discharge/ventilation accessories, see

the FLUE PIPE ACCESSORIES MANUAL.

 

Exhaust

Restrictor

Maximum

Risk of Condensation Forming

10 RFFI

Type

ø 44 mm

Extension

Piping not insulated

Piping insulated

 

 

Exhaust/Air

ø 44 restrictor

NO restrictor

ø 44 restrictor

NO restrictor

Coaxial

C12 (xx)

L min = 0.5 m

L = 5 m

 

 

 

 

Systems

C32 (xx)

NONE

NONE

NONE

NONE

L max = 1 m

ø 60/100

C42 (xx)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TABLE 2.1

2.10ROOM THERMOSTAT CONNECTION

To connect a room thermostat and/or time clock, it is necessary to:

1. - Open the control panel as indicated in section 4.3;

2.- Remove screws “A” and remove the inspection cover from the reverse of the control panel;

3.- For the room-thermostat connect the thermostat switching wires to the position 5 and 6 and remove the wire link (for three-wire thermostats connect the neutral to terminal N);

4.- For the time clock connect the clock switching wires to the positions 3 and 4 and connect the clock motor electrical supply to the terminals marked L and N.

Note: A frost thermostat is built-in to the appliance.

For connection to control systems with zone valves for hot water cylinders see section 3.

A

9

Image 9
Contents Installation Instructions Type C Boilers Table of Contents General Instructions Installation Overall ViewReference Standards Siting the Appliance Overall DimensionsClearances Mounting the Appliance Electrical ConnectionWater Connections GAS ConnectionResidual Head of the Boiler Tower Flue Components Flue ConnectionsRoom Thermostat Connection RffiOn/Off Switch Electrical DiagramGAS and Water Circuits H.W. Storage Cylinder 2 Port and 3 Port Valve InstallationsModel Commissioning Domestic HOT Water Priority KITInitial Preparation Removing the Front Panel Control PanelFume Discharge Monitoring Initial START-UP Combustion AnalysisBoiler Safety Systems Draining the System GAS Adjustments RffiChanging the Type of GAS Maintenance Number 41-116-04 Technical InformationServicing Instructions Type C Boilers Fault Finding To Gain General Access Replacement of PartsServicing Instructions Removing the front panelRemoving the side panels Removing the sealed chamber front coverRemoving the combustion cover Access to the Combustion ChamberRemoving the burner and jets Removing the electrodesRemoving the main heat exchanger Removing the fan Removing the air pressure switchServicing and Removal of the GAS Valve Setting the gas pressuresRffi Removing the gas valve Removing the spark generatorRemoving the safety valve Removing the pump pressure switchAccess to the Water Circuit Removing the automatic air vent 1. Unscrew valve top Z FIGRemoving the pump Removing the expansion vessel Removing the pressure gaugeRemoving the overheat thermostat Removing the frost thermostatRemoving the regulation thermostat Access to the Control System Checking the fuseRemoving the P.C.B.s Fault Finding Fault Finding GuideFlow -CHARTS YES Mbar Electrical DiagramsSF008A MicroSYSTEM 10 Rffi Ariston B063 Technical Service Hot Line 01494 23 99 84 1582

41-116-04 specifications

The Ariston 41-116-04 is a remarkable piece of technology that epitomizes modern design and performance in the home appliance sector. This innovative unit stands out for its blend of practicality and sophistication, making it a favorite among consumers seeking efficiency and elegance in their daily lives.

At the heart of the Ariston 41-116-04 lies its impressive energy efficiency. This appliance boasts an advanced A+ energy rating, ensuring minimal energy consumption while still delivering optimal performance. This not only contributes to lowering utility bills but also aligns with environmentally friendly practices, making it a responsible choice for eco-conscious consumers.

One of the key features of the Ariston 41-116-04 is its user-friendly interface. With intuitive controls and a clear digital display, users can easily navigate through various settings and options. This thoughtful design simplifies operation, allowing for a seamless experience whether you are a tech-savvy individual or someone who prefers straightforward functionality.

The versatility of the Ariston 41-116-04 is another considerable advantage. It offers multiple modes tailored for different cooking styles, ensuring that meals can be prepared to perfection regardless of the dish. Whether you need to bake, grill, or steam, this model provides an array of cooking options that cater to diverse culinary preferences.

The appliance also incorporates innovative technologies to enhance performance. For instance, the advanced heat distribution system ensures even cooking results, eliminating hotspots and guaranteeing uniformly cooked meals. The incorporation of high-quality materials in its construction offers durability and robust performance, an essential characteristic for any long-lasting appliance.

In terms of safety, the Ariston 41-116-04 is designed with multiple safety features, including an automatic shut-off and child lock functions. These elements provide peace of mind for families, knowing that safety is a priority in all operations.

In conclusion, the Ariston 41-116-04 is a stellar appliance that encompasses efficiency, user-friendliness, and advanced cooking technologies. With its emphasis on energy conservation and safety, it represents an excellent investment for any modern household looking to enhance their culinary experience while maintaining a commitment to sustainability.