Ariston 41-116-04 installation instructions MicroSYSTEM 10 Rffi

Page 41

4.SHORT SPARE PARTS LIST

microSYSTEM 10 RFFI

1

2

3

4

5

6

7

70 11

69 68 67

66 65

64

63

62

61

 

 

 

 

 

 

60

 

 

 

 

 

 

59

 

 

 

 

11

 

58

 

 

 

 

 

 

71

 

 

 

 

63

 

 

63

 

 

 

72

11

 

 

 

 

 

11

107

 

104

 

 

105

 

106

103

73

 

 

 

 

 

 

75

 

 

 

304

301

302

303

57

8

9

10

11

12

13

14

15

16 17

13 19

18

19

20

21 22 23

74

 

102

56

76

101

 

 

55

 

77

 

 

 

77

 

54

 

 

 

78

99

53

 

 

 

 

 

11

78

 

100

98

52

12

 

79

51

 

 

 

97

 

81

 

 

13

 

 

 

 

 

80

 

 

 

 

96

 

 

 

83

 

 

 

 

 

50

 

 

85

 

 

 

 

82

84

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

47

49

 

 

 

 

 

 

 

 

 

 

86

88

 

 

95

 

48

 

 

89

91

 

 

 

47

 

 

 

 

94

 

 

 

87

 

 

 

 

 

 

 

 

 

 

 

 

 

92

93

 

46

 

 

 

 

31

 

 

 

 

90

 

 

 

45

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

24

13

25 26 27

28 29 30

31 32

33 34 35

36

37 38 39 38 37 38 40 41 42

43

44

33 352

351

353

354

 

10/15 RFFI

 

 

 

 

 

 

 

MODELS

CHARACTERISTICS

SERIAL NO:

REF.

 

 

 

VALIDITY

 

 

MICROSYSTEM 10 RFFI

METHANE

2320021100001

A

 

 

 

 

 

 

MICROSYSTEM 10 RFFI

LPG

2320021100001

B

 

 

 

 

 

 

MICROSYSTEM 15 RFFI

METHANE

2320021100001

C

ES003A

MICROSYSTEM 15 RFFI

LPG

2320021100001

D

 

B063

21

Image 41 Contents
Installation Instructions Type C Boilers Table of Contents General Instructions Reference Standards InstallationOverall View Siting the Appliance Overall DimensionsClearances Mounting the Appliance Electrical ConnectionWater Connections GAS ConnectionResidual Head of the Boiler Tower Flue Components Flue ConnectionsRoom Thermostat Connection RffiOn/Off Switch Electrical DiagramGAS and Water Circuits H.W. Storage Cylinder 2 Port and 3 Port Valve InstallationsModel Initial Preparation CommissioningDomestic HOT Water Priority KIT Removing the Front Panel Control PanelFume Discharge Monitoring Initial START-UP Combustion AnalysisBoiler Safety Systems Draining the System Changing the Type of GAS GAS AdjustmentsRffi Maintenance Number 41-116-04 Technical InformationServicing Instructions Type C Boilers Fault Finding To Gain General Access Replacement of PartsServicing Instructions Removing the front panelRemoving the side panels Removing the sealed chamber front coverRemoving the combustion cover Access to the Combustion ChamberRemoving the burner and jets Removing the electrodesRemoving the main heat exchanger Removing the fan Removing the air pressure switchServicing and Removal of the GAS Valve Setting the gas pressuresRffi Removing the gas valve Removing the spark generatorRemoving the safety valve Removing the pump pressure switchAccess to the Water Circuit Removing the automatic air vent 1. Unscrew valve top Z FIGRemoving the pump Removing the expansion vessel Removing the pressure gaugeRemoving the regulation thermostat Removing the overheat thermostatRemoving the frost thermostat Removing the P.C.B.s Access to the Control SystemChecking the fuse Flow -CHARTS Fault FindingFault Finding Guide YES Mbar Electrical DiagramsSF008A MicroSYSTEM 10 Rffi Ariston B063 Technical Service Hot Line 01494 23 99 84 1582