Ariston 41-116-04 Removing the pump pressure switch, Removing the safety valve

Page 31

1.5ACCESS TO THE WATER CIRCUIT

Important! Before any component is removed, the boiler must be drained of all water.

1.5.1 Removing the pump pressure switch

1.Remove the cable of the pump pressure switch “W” (Fig. 1.31);

2.Unscrew the pump pressure switch by using a spanner on the nut “X”(FIG. 1.32);

3.Remove the pump pressure switch.

W

FIG. 1.31

X

FIG. 1.32

1. 5. 2 Removing the safety valve

1.Loosen nut “Y” (FIG. 1.33);

2.Disconnect the discharge pipe work from below the boiler;

3.Unscrew and remove the valve.

Y

FIG. 1.33

1.5.3Removing the automatic air vent 1. Unscrew valve top “Z” (FIG. 1.34);

2. Remove valve complete with float (FIG 1.35).

Z

FIG. 1.34

FIG. 1.35

11

Image 31 Contents
Installation Instructions Type C Boilers Table of Contents General Instructions Overall View InstallationReference Standards Mounting the Appliance Electrical Connection Overall DimensionsSiting the Appliance ClearancesWater Connections GAS ConnectionResidual Head of the Boiler Tower Flue Components Flue ConnectionsRoom Thermostat Connection RffiOn/Off Switch Electrical DiagramGAS and Water Circuits H.W. Storage Cylinder 2 Port and 3 Port Valve InstallationsModel Domestic HOT Water Priority KIT CommissioningInitial Preparation Removing the Front Panel Control PanelFume Discharge Monitoring Initial START-UP Combustion AnalysisBoiler Safety Systems Draining the System Rffi GAS AdjustmentsChanging the Type of GAS Maintenance Number 41-116-04 Technical InformationServicing Instructions Type C Boilers Fault Finding Removing the front panel Replacement of PartsTo Gain General Access Servicing InstructionsRemoving the side panels Removing the sealed chamber front coverRemoving the electrodes Access to the Combustion ChamberRemoving the combustion cover Removing the burner and jetsRemoving the main heat exchanger Removing the fan Removing the air pressure switchServicing and Removal of the GAS Valve Setting the gas pressuresRffi Removing the gas valve Removing the spark generatorRemoving the automatic air vent 1. Unscrew valve top Z FIG Removing the pump pressure switchRemoving the safety valve Access to the Water CircuitRemoving the pump Removing the expansion vessel Removing the pressure gaugeRemoving the frost thermostat Removing the overheat thermostatRemoving the regulation thermostat Checking the fuse Access to the Control SystemRemoving the P.C.B.s Fault Finding Guide Fault FindingFlow -CHARTS YES Mbar Electrical DiagramsSF008A MicroSYSTEM 10 Rffi Ariston B063 Technical Service Hot Line 01494 23 99 84 1582