1.2OVERALL VIEW

LEGEND:

1.Flue connector

2.Fan

3.Combustion chamber hood

4.Main heat exchanger

5.Safety thermostat

6.Combustion chamber

7.Combustion chamber insulation panel

8.Detection electrode

9.Ignition electrodes

10.Burner

11.Regulation thermostat

12.Frost thermostat

13.Pump pressure switch

14.Safety valve (3 bar)

15.Automatic By-pass

16.Gas valve

17.Spark generator

18.Boiler drain valve

19.Circulation pump with automatic air release valve

20.Expansion vessel

21.Air pressure take-off point

22.Air pressure switch

23.Combustion analysis points

2.INSTALLATION

2.1REFERENCE STANDARDS

FIG. 1.0

The technical information and instructions provided herein below are intended for the installer so that the unit may be installed correctly and safely.

The installation and initial start up of the boiler must be by a CORGI Registered Installer in compliance with the installation standards currently in effect, as well as with any and all local health and safety standards i.e. CORGI .

This appliance must be installed by a competent installer in accordance with current Gas Safety (installation & use) Regulations.

The installation of this appliance must be in accordance with the relevant requirements of the current Gas Safety (installation & use) Regulations, the Local Building Regulations, the current I.E.E. Wiring Regulations, the byelaws of the local water authority, and in Scotland, in accordance with the Building Standards (Scotland) Regulation and Health and Safety document No. 635 “Electricity at work regulations 1989”.

Installation should also comply with the following British Standard Codes of Practice:

BS 7593:1992

Treatment of water in domestic hot water central

 

heating systems

BS 5546:1990

Installation of hot water supplies for domestic

 

purposes

BS 5440-1:1990

Flues

BS 5440-2:1989

Air supply

BS 5449:1990

Forced circulation hot water systems

BS 6789:1987

Installation of gas fired hot water boilers of rated

 

input not exceeding 60kW

BS 6891:1989

Installation of low pressure gas pipe up to 28mm

BS 7671:1992

IEE wiring regulations

BS 4814:1990

Specification for expansion vessels

BS 5482:1994

Installation of LPG

4

Image 4 Contents
Installation Instructions Type C Boilers Table of Contents General Instructions Overall View InstallationReference Standards Overall Dimensions Siting the ApplianceClearances Mounting the Appliance Electrical ConnectionGAS Connection Water ConnectionsResidual Head of the Boiler Flue Connections Tower Flue ComponentsRffi Room Thermostat ConnectionElectrical Diagram On/Off SwitchGAS and Water Circuits 2 Port and 3 Port Valve Installations H.W. Storage CylinderModel Domestic HOT Water Priority KIT CommissioningInitial Preparation Control Panel Removing the Front PanelInitial START-UP Combustion Analysis Fume Discharge MonitoringBoiler Safety Systems Draining the System Rffi GAS AdjustmentsChanging the Type of GAS Maintenance Technical Information Number 41-116-04Servicing Instructions Type C Boilers Fault Finding Replacement of Parts To Gain General AccessServicing Instructions Removing the front panelRemoving the sealed chamber front cover Removing the side panelsAccess to the Combustion Chamber Removing the combustion coverRemoving the burner and jets Removing the electrodesRemoving the main heat exchanger Removing the air pressure switch Removing the fanSetting the gas pressures Servicing and Removal of the GAS ValveRffi Removing the spark generator Removing the gas valveRemoving the pump pressure switch Removing the safety valveAccess to the Water Circuit Removing the automatic air vent 1. Unscrew valve top Z FIGRemoving the pump Removing the pressure gauge Removing the expansion vesselRemoving the frost thermostat Removing the overheat thermostatRemoving the regulation thermostat Checking the fuse Access to the Control SystemRemoving the P.C.B.s Fault Finding Guide Fault FindingFlow -CHARTS YES Mbar Diagrams ElectricalSF008A MicroSYSTEM 10 Rffi Ariston B063 Technical Service Hot Line 01494 23 99 84 1582