Ariston 41-116-04 installation instructions Boiler Safety Systems Draining the System

Page 17

4.7BOILER SAFETY SYSTEMS

4.8DRAINING THE SYSTEM

The boiler is fitted with the following devices (see section 4.2 for references).

1 - IGNITION FAILURE:

This indicates ignition failure when a flame is not detected within 7 seconds of starting an ignition sequence. The L.E.D. “F” will illuminate to signal the shutdown status.

The system can be reset by pressing and releasing the button “E” after checking to make sure that the gas cock is open.

2 - INSUFFICIENT SYSTEM PRESSURE:

In the event of insufficient water pressure in the heating system, a safety device will shutdown the boiler. Check the system pressure on the pressure gauge “J” and if it is less than 0.4 bar refill the system to 1.5 bar. Once the system pressure is at the correct level the boiler will ignite automatically.

3 - OVERHEATING:

This control shuts off the boiler in the case where the primary circuit reaches a temperature in excess of 105°C.

The red L.E.D. “F” will illuminate to signal this shutdown status.

The system can be reset by waiting a few minutes for the primary exchanger to cool down and then by pressing and releasing the “E” button.

4.ANTI-FROST DEVICE:

The boiler is equipped with a device that, in the event of the water temperature going below 6°C, the burner ignites at the minimum power until the boiler water reaches a temperature of 16°C.

This device operates only if the boiler is functioning perfectly and:

-the system pressure is sufficient;

-the boiler is powered electrically - L.E.D. “B” illuminated;

-the gas is turned on.

5 - EXHAUST DISCHARGE ANOMALY SHUTDOWN:

The boiler is fitted with safety devices, which in the event of defective discharge of exhaust fumes, automatically interrupts the gas supply, thereby shutting off the boiler.

The shutdown of the boiler is temporary and when the discharge state of exhaust fumes has returned to normal, the boiler automatically turns back on

The heating system must be emptied as follows:

-Turn off the boiler;

-Attach a hose pipe and open the drain valve;

-Empty the system at the lowest points (where present). When the heating system is unused for an extended period of time, it is recommended that you add antifreeze with an ethylene glycol base to the water in the heating lines and radiators if the ambient temperature drops below 0°C during the winter.

This makes repeated draining of the entire system unnecessary.

17

Image 17
Contents Installation Instructions Type C Boilers Table of Contents General Instructions Reference Standards InstallationOverall View Siting the Appliance Overall DimensionsClearances Mounting the Appliance Electrical ConnectionWater Connections GAS ConnectionResidual Head of the Boiler Tower Flue Components Flue ConnectionsRoom Thermostat Connection RffiOn/Off Switch Electrical DiagramGAS and Water Circuits H.W. Storage Cylinder 2 Port and 3 Port Valve InstallationsModel Initial Preparation CommissioningDomestic HOT Water Priority KIT Removing the Front Panel Control PanelFume Discharge Monitoring Initial START-UP Combustion AnalysisBoiler Safety Systems Draining the System Changing the Type of GAS GAS AdjustmentsRffi Maintenance Number 41-116-04 Technical InformationServicing Instructions Type C Boilers Fault Finding To Gain General Access Replacement of PartsServicing Instructions Removing the front panelRemoving the side panels Removing the sealed chamber front coverRemoving the combustion cover Access to the Combustion ChamberRemoving the burner and jets Removing the electrodesRemoving the main heat exchanger Removing the fan Removing the air pressure switchServicing and Removal of the GAS Valve Setting the gas pressuresRffi Removing the gas valve Removing the spark generatorRemoving the safety valve Removing the pump pressure switchAccess to the Water Circuit Removing the automatic air vent 1. Unscrew valve top Z FIGRemoving the pump Removing the expansion vessel Removing the pressure gaugeRemoving the regulation thermostat Removing the overheat thermostatRemoving the frost thermostat Removing the P.C.B.s Access to the Control SystemChecking the fuse Flow -CHARTS Fault FindingFault Finding Guide YES Mbar Electrical DiagramsSF008A MicroSYSTEM 10 Rffi Ariston B063 Technical Service Hot Line 01494 23 99 84 1582

41-116-04 specifications

The Ariston 41-116-04 is a remarkable piece of technology that epitomizes modern design and performance in the home appliance sector. This innovative unit stands out for its blend of practicality and sophistication, making it a favorite among consumers seeking efficiency and elegance in their daily lives.

At the heart of the Ariston 41-116-04 lies its impressive energy efficiency. This appliance boasts an advanced A+ energy rating, ensuring minimal energy consumption while still delivering optimal performance. This not only contributes to lowering utility bills but also aligns with environmentally friendly practices, making it a responsible choice for eco-conscious consumers.

One of the key features of the Ariston 41-116-04 is its user-friendly interface. With intuitive controls and a clear digital display, users can easily navigate through various settings and options. This thoughtful design simplifies operation, allowing for a seamless experience whether you are a tech-savvy individual or someone who prefers straightforward functionality.

The versatility of the Ariston 41-116-04 is another considerable advantage. It offers multiple modes tailored for different cooking styles, ensuring that meals can be prepared to perfection regardless of the dish. Whether you need to bake, grill, or steam, this model provides an array of cooking options that cater to diverse culinary preferences.

The appliance also incorporates innovative technologies to enhance performance. For instance, the advanced heat distribution system ensures even cooking results, eliminating hotspots and guaranteeing uniformly cooked meals. The incorporation of high-quality materials in its construction offers durability and robust performance, an essential characteristic for any long-lasting appliance.

In terms of safety, the Ariston 41-116-04 is designed with multiple safety features, including an automatic shut-off and child lock functions. These elements provide peace of mind for families, knowing that safety is a priority in all operations.

In conclusion, the Ariston 41-116-04 is a stellar appliance that encompasses efficiency, user-friendliness, and advanced cooking technologies. With its emphasis on energy conservation and safety, it represents an excellent investment for any modern household looking to enhance their culinary experience while maintaining a commitment to sustainability.