17)Test thermostat operation while the boiler is running. Turn the thermostat to the lowest setting. For standing pilot boiler models, pilot burner should remain lit but the main burners should stop firing. For intermittent ignition boiler models both pilot burner and main burners should stop firing. Raise the thermostat back to the highest setting. The main burners (for standing pilot boiler models) or pilot burner and main burners (for intermittent ignition boiler models) should relight.

18)Verify low water cutoff operation while the boiler is running. Slowly open drain valve and drain boiler until the water level drops below low water cutoff line. Water still should be visible in the gauge glass when the low water cutoff shuts down the main burners. For standing pilot boiler models, pilot burner should remain lit when the main burners stop firing. For intermittent ignition boiler models both pilot burner and main burners should stop firing. Make sure pressure limit, thermostat or other controls have not shut off the boiler. Upon test completion refill the boiler to the normal water level.

19)Check pressure limit control operation. When steam pressure is registered on pressure gauge, lower pressure limit setting below gauge reading. For standing pilot boiler models, pilot burner should remain lit when the main burners stop firing. For intermittent ignition boiler models, both pilot burner and main burners should stop firing. Raise pressure limit setting above gauge reading. The main burners( for standing pilot boiler models) or pilot burner and main burners ( for intermittent ignition boiler models) should relight.

20)After the boiler has operated for approximately 30 minutes, check the boiler and heating system piping for leaks. Repair any leaks found at once.

21)Inspect the vent system for flue gas leaks. Repair any leaks found before leaving the boiler in operation.

22)Replacement of a steam boiler tends to break loose accumulated scale from the system. During the first week of operation, blow down the #67 low water cut-off at least three times following the blow down instructions on the yellow sticker adjacent to the low water cut-off.

23)After new boiler has been installed and put into continuous operation for several days, clean the boiler of oil, grease, sludge, and other contaminants that may have been present in existing piping. This will prevent unsteady water line and water carry over into supply main. The boiler boil-out should be done as follows:

a)Turn off gas supply to boiler per the appropriate Lighting and Operating instructions on page 25 - 28.

b)Drain water from boiler until about one inch of water is visible in gauge glass.

c)Run a hose or temporary piping from the boiler drain valve to a location where hot water can be safely discharged. Drain approximately five gallons of water from the boiler and mix-in an appropriate amount of an approved boil-out compound. Remove safety valve and refill the boiler with prepared solution through funnel inserted into elbow under the safety valve. Run a hose or temporary piping from safety valve tapping to a location where hot water can be safelydischarged.DONOTINSTALLANYVALVESINTHISLINE.

d)Light off the boiler per the appropriate instructions on page 25 - 28. Run boiler for several hours, boiling the water, without generating steam pressure. Open the water feed valve sufficiently to allow a slight overflow of water through the safety valve tapping drain line. Continue boiling until water coming out is clear.

30

29

Image 30
Contents BSI Series Table of Contents Product DescriptionII Specifications BSI SpecificationsIII Before Installing IV Locating the BoilerAir for Combustion and Ventilation For Buildings of Other than Unusually Tight Construction ForBuildingsofUnusuallyTightConstructionBOILERINSTALLEDINCONFINEDSPACE, ALL AIR from Inside ALL AIR from OUTDOORS, Using Openings Into Boiler Room VI Venting Removing an Existing Boiler from a Common Chimney BSI Boilertypicalventsystem Installation and Components VII Gas Piping GasconnectiontoboilerViii System Piping General Piping NotesPipingInstallation Common NEAR-BOILER Piping Mistakes IX Indirect Water Heater Piping Indirectwater Heater BOILER-SIDE PipingWiring Indirect Water Heater Wiring Wiring Indirectwater Heater to Boiler BSI Control System Sequence of Operation Sequence of Operation, Standing PilotVent Damper Note Less Vent GAS Valve BSI379 Honeywell VR8204/VR8304 Series GAS Valves BSI069 Robertshaw XI Start-up and Checkout 2423Standing Pilot Burner Flame For Your Safety Read Before Operating For Your Safety Read Before Lighting For Your Safety Read Before Lighting Position Indicator High Altitude Burners GASVALVEDETAIL-HONEYWELLVR8200ORVR8300STANDINGPILOT On at least a weekly basis XII Service and MaintenanceOn a continuous basis On an annual basisPage Heat Exchanger Cleaning Procedure Xiii Troubleshooting Start END Start END Standing Pilot Ignition System Troubleshooting Chart Intermittent Ignition System Troubleshooting Chart XIV Parts Page KEY # Page Boilers only Page Appendix a Knockdown Boiler Assembly Instructions Before InstallingFIGUREA1 BASE, Heat EXCHANGER, Flue Collector Assembly Gas Valve Installation Figure A2 Jacket Installation Electrical Wiring Connections Complete InstallationFigure A3 Tapping Locations see Text for Tapping Uses Crown

BSI069, BSI345, BSI207, BSI172, BSI241 specifications

Crown Boiler Company is renowned for its high-quality heating solutions, with a diverse range of models designed to meet various residential and commercial needs. Among their popular offerings are the BSI series, which includes the BSI379, BSI138, BSI310, BSI276, and BSI103 models. Each of these boilers comes with distinct features, technologies, and characteristics that cater to different applications and preferences.

The Crown Boiler BSI379 is a powerful and efficient boiler designed for residential use. It features a stainless steel heat exchanger that enhances durability and improves heat transfer efficiency. The BSI379 operates on natural gas, providing a high thermal efficiency rating which helps to reduce energy costs. With a compact design, it can fit conveniently in various installations, making it a versatile choice for homeowners.

The BSI138 model is another excellent option for smaller residential spaces. It is equipped with advanced technology that allows for quiet operation and minimal environmental impact. This boiler also offers a straightforward control interface, making it easy for homeowners to adjust settings according to their heating needs. The BSI138's lightweight construction and small footprint allow for flexible installation options.

Moving on to the BSI310, this model is designed for medium to larger-sized homes. It features an electronic ignition system that ensures reliable start-up while minimizing gas consumption. The BSI310 also incorporates multiple safety features, including pressure relief valves and limit controls, enhancing user safety during operation. Its robust design ensures efficient heating even in the coldest months.

The BSI276 model is characterized by its sealed combustion design, which improves indoor air quality by preventing drafts and ensuring that all combustion air is drawn from outside. This model is ideal for energy-conscious homeowners seeking environmentally friendly options. Its high-efficiency rating translates to significant energy savings over time, making it a financially wise investment.

Finally, the BSI103 is an entry-level model that retains the quality and reliability associated with Crown Boilers. It is particularly suited for smaller homes or apartments and offers ease of use and maintenance. The BSI103 combines affordability with efficiency, providing a cost-effective heating solution without compromising on performance.

In summary, the Crown Boiler BSI series, comprising the BSI379, BSI138, BSI310, BSI276, and BSI103, showcases a blend of innovative technologies and features. With options suitable for various household sizes and energy needs, Crown Boiler continues to deliver reliable heating solutions that cater to modern homeowners’ demands for efficiency, safety, and convenience. Each model's unique characteristics ensure that users can find the perfect boiler to meet their heating requirements.