Eagle Home Products
Eagle Series
instruction manual
Portable Multi-Gas Detector
Specs
Parts list
Alarm Lights
Returning to Default Settings
Warranty
Maintenance
Resetting Gas Alarms
CAL/SETUP Switch
To use the float probe assembly
Battery Voltage Screen
Page 1
Instruction Manual
Eagle Series
Portable
Multi-Gas
Detector
Part Number:
71-0028RK
Edition: Third
Released: July 2001
RKI Instruments, Inc. • 1855 Whipple Rd. • Hayward, CA 94544 • (510)
441-5656
Page 1
Page 2
Image 1
Page 1
Page 2
Contents
RKI Instruments, Inc Whipple Rd. Hayward, CA 94544 510
Portable Multi-Gas Detector
Warranty
Warranty
Table of Contents
Table of Contents
Display Mode
Calibration
Appendix F Eagle Tank Tester Model
Overview
Introduction
Introduction
About this Manual
Specifications
Specifications
Eagle Specifications
Combustible Oxygen
Standard Sensor Specifications
Carbon
Case
Description
Control Panel
Buttons
Battery Charger Connector
Alarm Lights
Interface Port
Buzzer
Sensors
CAL/SETUP Switch
Methane Elimination Switch
Circuit Boards
Starting Up the Eagle
Operation
Operation
Operation
Monitoring Combustible Gas in the PPM Range
Normal Operation
Monitoring Combustible Gases Other than Methane
Full Response Mode Conversion Factors Methane Calibration
Target Gas LEL Factor
Turning Off the Eagle
Setting User Access
Alarm Indications
Alarms
Alarms
Stel alarm toxics only
Low flow alarm
Sensor failure alarm and emergency operation
Resetting Gas Alarms
Display Mode
Display Mode
User and Station ID Screen
Elapsed Time Screen
Peak Screen
To enter a user and station ID
TWA/STEL Screen
Battery Voltage Screen
Date/Time Screen
Remaining Log Time Screen
Clear Data Logger Screens
To clear the data log
Tips for Using Setup Mode
Setup Mode
Setup Mode
Updating the Battery Type Setting
Entering Setup Mode
Updating Channel Settings
Setting a custom target gas label
Target Gas
Fullscale PPM Readings Equivalent to 100% LEL
Updating oxygen channel settings
Updating toxics channel settings
Setting a custom target gas label
Updating Combustible Gas Channel Units of Measure
Updating the Alarm Point Settings
Updating the Eagle’s Serial Number
Updating the Lunch Break Setting
Updating the Alarm Silence Setting
Updating the Alarm Latching Setting
Turning the User ID Function On or Off
Updating the Auto Calibration Settings
Turning the Auto Fresh Air Function On or Off
Updating the Back Light Setting
Updating Log Data Over Write Setting data log option
Updating the Interval Time Setting data log option
Updating the Date and Time Settings data log option
Updating the Time Calibration Setting data log option
Updating the Confirmation Beep Setting
Updating the Zero Follow Settings
Returning to Default Settings
To reset all default alarm point settings
To reset all default settings
To reset the oxygen zero setting
Calibration Supplies and Equipment
Calibration
Preparing for Calibration
Calibration
Calibrating the Eagle
Calibration
Calibrating with the Single Calibration method
Calibration
Displaying the Battery Voltage
Maintenance
To display the battery voltage
Replacing Alkaline Batteries
To replace the combustibles sensor
Replacing Sensors
To replace the oxygen sensor
To replace the H2S or CO sensor
Parts List
Appendix a Parts List
Appendix a Parts List
Part Number Description
Part Number
Appendix B Methane Elimination
Appendix B Methane Elimination
Monitoring combustible gases other than hexane
Specifications
Appendix C Non-Standard Toxic Gas Sensors
Description
Non-Standard Toxic Gas Sensors Specifications
Calibrating Non-Standard Toxic Gas Sensors
Adjusting the sensor controls
Replacing Non-Standard Toxic Gas Sensors
Parts List Non-Standard Toxic Gas Sensors
Parts List
Appendix D Carbon Dioxide Sensors
Alarm TWA Alarm Stel Alarm
Carbon Dioxide Sensor Specifications
Appendix D Carbon Dioxide Sensors
Demand Zero for Carbon Dioxide Sensors
Normal Operation of Carbon Dioxide Sensors
Calibrating Carbon Dioxide Sensors
Carbon Dioxide Fresh Air Readings
Adjusting the sensor controls
Replacing Carbon Dioxide Sensors
Parts List Carbon Dioxide Sensors
Appendix E Infrared Methane Sensors
Range Alarm TWA Alarm Stel Alarm
Target Gases
Infrared Methane Sensor Specifications
Sensor Analog PCB Socket
Calibrating Infrared Methane Sensors
Replacing Infrared Methane Sensors
Parts List Infrared Methane Sensors
Appendix F Eagle Tank Tester Model
To use the float probe assembly
To eliminate an oxygen alarm that is not being used
Alarms
To attach the dilution fitting
Appendix F Eagle Tank Tester Model
Calibration
Parts List Eagle Tank Tester Model
Displaying Additional Channels
Appendix G Five-Gas and Six-Gas Models
Appendix G Five-Gas and Six-Gas Models
Calibration, Display, and Setup Modes
Appendix H Eagle Transformer Gas Tester Model
Appendix H Eagle Transformer Gas Tester Model
Alarms
Appendix I Installing the Data Logger Board
Appendix I Installing the Data Logger Board
Top
Page
Image
Contents