Eagle Home Products Eagle Series instruction manual Appendix a Parts List, Part Number Description

Page 56

Appendix A: Parts List

Table 6 lists part numbers for the Eagle’s replacement parts and accessories.

 

Table 6: Parts List

Part Number

Description

13-0100RK

Shoulder strap

20-0640RK

Carrying case (for Eagle and standard accessories)

20-0642RK

Carrying case (for Eagle, standard accessories, and calibration kit)

30-0600RK-01

Pump

33-0156RK-01

Filter element (for hydrophobic filter; pack of 5)

33-0160RK

Filter, internal dust filter

33-6091RK

Filter, charcoal filter

35-0110RK

Dummy sensor, toxic gas sensor position

35-0111RK

Dummy sensor, oxygen sensor position

35-0112RK

Dummy sensor, combustible gas sensor position

49-1140RK

Alkaline battery, D-size (total of 4 required)

49-1240RK

Ni-Cd battery, D-size (total of 4 required)

49-2149RK

Battery charger, 220 VAC

49-2150RK

Battery charger, 115 VAC (with alkaline battery recognition)

49-2151RK

Battery charger, 12 VDC (with cigarette lighter plug)

49-2152RK

Continuous operation adapter, 115 VAC (with 20-foot cable)

49-2153RK

Continuous operation adapter, 12 VDC (with cigarette lighter plug)

52-0206RK

Lapel buzzer

52-2034RK

Remote audible alarm (with 20-foot cable)

52-2035RK

Remote audible alarm and strobe light (with 20-foot cable)

57-0012RK

Datalogging board (also requires 82-5007RK)

62-0125RK

Sensor, combustible gas (hydrocarbon)

65-0601RK

Sensor, oxygen

65-2005RK

Sensor, carbon monoxide

65-2035RK

Sensor, hydrogen sulfide

71-0028RK

Eagle Instruction Manual

50 • Appendix A: Parts List

Eagle Instruction Manual

Image 56 Contents
Portable Multi-Gas Detector RKI Instruments, Inc Whipple Rd. Hayward, CA 94544 510Warranty WarrantyTable of Contents Display Mode Table of ContentsCalibration Appendix F Eagle Tank Tester Model Introduction IntroductionOverview About this Manual Eagle Specifications SpecificationsSpecifications Carbon Standard Sensor SpecificationsCombustible Oxygen Description CaseControl Panel ButtonsAlarm Lights Battery Charger ConnectorInterface Port BuzzerSensors Circuit Boards Methane Elimination SwitchCAL/SETUP Switch Operation OperationStarting Up the Eagle Operation Normal Operation Monitoring Combustible Gas in the PPM RangeTarget Gas LEL Factor Full Response Mode Conversion Factors Methane CalibrationMonitoring Combustible Gases Other than Methane Setting User Access Turning Off the EagleAlarms AlarmsAlarm Indications Stel alarm toxics only Low flow alarm Sensor failure alarm and emergency operation Resetting Gas Alarms User and Station ID Screen Display ModeDisplay Mode To enter a user and station ID Peak ScreenElapsed Time Screen Date/Time Screen Battery Voltage ScreenTWA/STEL Screen To clear the data log Clear Data Logger ScreensRemaining Log Time Screen Setup Mode Setup ModeTips for Using Setup Mode Entering Setup Mode Updating the Battery Type SettingUpdating Channel Settings Setting a custom target gas label Fullscale PPM Readings Equivalent to 100% LEL Target GasUpdating oxygen channel settings Updating toxics channel settings Setting a custom target gas label Updating Combustible Gas Channel Units of Measure Updating the Alarm Point Settings Updating the Lunch Break Setting Updating the Eagle’s Serial NumberUpdating the Alarm Latching Setting Updating the Alarm Silence SettingUpdating the Auto Calibration Settings Turning the User ID Function On or OffUpdating the Back Light Setting Turning the Auto Fresh Air Function On or OffUpdating the Interval Time Setting data log option Updating Log Data Over Write Setting data log optionUpdating the Time Calibration Setting data log option Updating the Date and Time Settings data log optionReturning to Default Settings Updating the Zero Follow SettingsUpdating the Confirmation Beep Setting To reset the oxygen zero setting To reset all default settingsTo reset all default alarm point settings Calibration Calibration Supplies and EquipmentPreparing for Calibration CalibrationCalibrating the Eagle Calibration Calibrating with the Single Calibration method Calibration Maintenance Displaying the Battery Voltage To display the battery voltage Replacing Alkaline BatteriesReplacing Sensors To replace the combustibles sensorTo replace the oxygen sensor To replace the H2S or CO sensor Appendix a Parts List Parts ListAppendix a Parts List Part Number DescriptionPart Number Appendix B Methane Elimination Appendix B Methane EliminationMonitoring combustible gases other than hexane Appendix C Non-Standard Toxic Gas Sensors SpecificationsDescription Non-Standard Toxic Gas Sensors SpecificationsCalibrating Non-Standard Toxic Gas Sensors Adjusting the sensor controls Replacing Non-Standard Toxic Gas Sensors Parts List Parts List Non-Standard Toxic Gas SensorsAlarm TWA Alarm Stel Alarm Appendix D Carbon Dioxide SensorsCarbon Dioxide Sensor Specifications Appendix D Carbon Dioxide SensorsNormal Operation of Carbon Dioxide Sensors Demand Zero for Carbon Dioxide SensorsCalibrating Carbon Dioxide Sensors Carbon Dioxide Fresh Air ReadingsAdjusting the sensor controls Replacing Carbon Dioxide Sensors Parts List Carbon Dioxide Sensors Range Alarm TWA Alarm Stel Alarm Appendix E Infrared Methane SensorsTarget Gases Infrared Methane Sensor SpecificationsCalibrating Infrared Methane Sensors Sensor Analog PCB SocketParts List Infrared Methane Sensors Replacing Infrared Methane SensorsTo use the float probe assembly Appendix F Eagle Tank Tester ModelAlarms To eliminate an oxygen alarm that is not being usedTo attach the dilution fitting Appendix F Eagle Tank Tester ModelParts List Eagle Tank Tester Model CalibrationAppendix G Five-Gas and Six-Gas Models Appendix G Five-Gas and Six-Gas ModelsDisplaying Additional Channels Calibration, Display, and Setup Modes Appendix H Eagle Transformer Gas Tester Model Appendix H Eagle Transformer Gas Tester ModelAlarms Appendix I Installing the Data Logger Board Appendix I Installing the Data Logger Board