Eagle Home Products Eagle Series instruction manual Alarms, Calibration, Display, and Setup Modes

Page 77

Cursors to the left of the first and last channels displayed indicate that additional channels are available before and after the currently displayed channels. Press the AIR/and SHIFT/buttons to display the remaining channels.

Alarms

If the Eagle recognizes an alarm condition for a non-displayed channel, the cursor flashes and the standard audible and visual alarms initiate.

If the alarm occurs for a channel before the top displayed channel, the cursor in the first line flashes. Press the AIR/button to display the channel in alarm.

If the alarm occurs for a channel after the bottom displayed channel, the cursor in the last line flashes. Press the SHIFT/button to display the channel in alarm.

Calibration, Display, and Setup Modes

For screens in these modes that display all active channels, a cursor displays:

in the top line if channels are available before the top line. Press the AIR/button to display the additional channel(s).

in the bottom line if channels are available after the bottom line. Press the SHIFT/button to display the additional channel(s).

in the top and bottom lines if channels are available before the top line and after the bottom line. Press the AIR/and SHIFT/buttons to display the additional channels.

Eagle Instruction Manual

Appendix G: Five-Gas and Six-Gas Models • 71

Image 77 Contents
RKI Instruments, Inc Whipple Rd. Hayward, CA 94544 510 Portable Multi-Gas DetectorWarranty WarrantyTable of Contents Table of Contents Display ModeCalibration Appendix F Eagle Tank Tester Model Introduction IntroductionOverview About this Manual Eagle Specifications SpecificationsSpecifications Carbon Standard Sensor SpecificationsCombustible Oxygen Case DescriptionControl Panel ButtonsBattery Charger Connector Alarm LightsInterface Port BuzzerSensors Circuit Boards Methane Elimination SwitchCAL/SETUP Switch Operation OperationStarting Up the Eagle Operation Monitoring Combustible Gas in the PPM Range Normal OperationTarget Gas LEL Factor Full Response Mode Conversion Factors Methane CalibrationMonitoring Combustible Gases Other than Methane Turning Off the Eagle Setting User AccessAlarms AlarmsAlarm Indications Stel alarm toxics only Low flow alarm Sensor failure alarm and emergency operation Resetting Gas Alarms User and Station ID Screen Display ModeDisplay Mode To enter a user and station ID Peak ScreenElapsed Time Screen Date/Time Screen Battery Voltage ScreenTWA/STEL Screen To clear the data log Clear Data Logger ScreensRemaining Log Time Screen Setup Mode Setup ModeTips for Using Setup Mode Updating the Battery Type Setting Entering Setup ModeUpdating Channel Settings Setting a custom target gas label Target Gas Fullscale PPM Readings Equivalent to 100% LELUpdating oxygen channel settings Updating toxics channel settings Setting a custom target gas label Updating Combustible Gas Channel Units of Measure Updating the Alarm Point Settings Updating the Eagle’s Serial Number Updating the Lunch Break SettingUpdating the Alarm Silence Setting Updating the Alarm Latching SettingTurning the User ID Function On or Off Updating the Auto Calibration SettingsTurning the Auto Fresh Air Function On or Off Updating the Back Light SettingUpdating Log Data Over Write Setting data log option Updating the Interval Time Setting data log optionUpdating the Date and Time Settings data log option Updating the Time Calibration Setting data log optionReturning to Default Settings Updating the Zero Follow SettingsUpdating the Confirmation Beep Setting To reset the oxygen zero setting To reset all default settingsTo reset all default alarm point settings Calibration Supplies and Equipment CalibrationPreparing for Calibration CalibrationCalibrating the Eagle Calibration Calibrating with the Single Calibration method Calibration Displaying the Battery Voltage MaintenanceTo display the battery voltage Replacing Alkaline BatteriesTo replace the combustibles sensor Replacing SensorsTo replace the oxygen sensor To replace the H2S or CO sensor Parts List Appendix a Parts ListAppendix a Parts List Part Number DescriptionPart Number Appendix B Methane Elimination Appendix B Methane EliminationMonitoring combustible gases other than hexane Specifications Appendix C Non-Standard Toxic Gas SensorsDescription Non-Standard Toxic Gas Sensors SpecificationsCalibrating Non-Standard Toxic Gas Sensors Adjusting the sensor controls Replacing Non-Standard Toxic Gas Sensors Parts List Non-Standard Toxic Gas Sensors Parts ListAppendix D Carbon Dioxide Sensors Alarm TWA Alarm Stel AlarmCarbon Dioxide Sensor Specifications Appendix D Carbon Dioxide SensorsDemand Zero for Carbon Dioxide Sensors Normal Operation of Carbon Dioxide SensorsCalibrating Carbon Dioxide Sensors Carbon Dioxide Fresh Air ReadingsAdjusting the sensor controls Replacing Carbon Dioxide Sensors Parts List Carbon Dioxide Sensors Appendix E Infrared Methane Sensors Range Alarm TWA Alarm Stel AlarmTarget Gases Infrared Methane Sensor SpecificationsSensor Analog PCB Socket Calibrating Infrared Methane SensorsReplacing Infrared Methane Sensors Parts List Infrared Methane Sensors Appendix F Eagle Tank Tester Model To use the float probe assemblyTo eliminate an oxygen alarm that is not being used AlarmsTo attach the dilution fitting Appendix F Eagle Tank Tester ModelCalibration Parts List Eagle Tank Tester ModelAppendix G Five-Gas and Six-Gas Models Appendix G Five-Gas and Six-Gas ModelsDisplaying Additional Channels Calibration, Display, and Setup Modes Appendix H Eagle Transformer Gas Tester Model Appendix H Eagle Transformer Gas Tester ModelAlarms Appendix I Installing the Data Logger Board Appendix I Installing the Data Logger Board