VENTING COMPONENTS & CONFIGURATION

The Champlain cannot be vented jointly with any other solid fuel or gas appliance. It must be vented directly to the outside of the building using a proper termination as listed in the manual. Your Champlain Direct Vent stove is approved for use with Simpson Dura-Vent’s GS Direct Vent, AmeriVent Direct, or Secure Vent systems. The venting configurations are shown in Figures 10 - 12. After determining the venting configuration for your stove, select the vent system that will accommodate your installation.

Caution: Make sure all stove and termination cap clearances have been observed per the Owner’s Manual.

Caution: Be sure there is no wiring or plumbing in the chosen location.

Caution: Venting terminals shall not be recessed into a wall or siding.

Note: If further direction is needed for installation, please refer to the venting instructions, which are provided with the venting system.

ACCEPTABLE DIRECT VENT

TERMINATION CAP LOCATIONS

The vent/air intake termination clearances above the high side of an angled roof are as follows:

Roof Pitch

Feet

Meters

Flat to 6/12

1

0.3

7/12 to 9/12

2

0.6

10/12 to 12/12

4

1.2

13/12 to 16/12

6

1.8

17/12 to 21/12

8

2.4

 

 

 

Listed below are components acceptable for installation. The venting system must be comprised of the appropriate venting components as specified.

APPROVED VENTING SYSTEM COMPONENTS

*Component Description

90 0 Elbow

45 0 Elbow

6" Straight

9" Straight

12" Straight

24" Straight

36" Straight

48" Straight

11"-14 5/8" Adjustable Pipe Length Horizontal Vent Cap

Vertical Vent Cap Snorkel 36”

Vinyl Siding Standoff 4 x 6 5/8” Round Ceiling Support Wall

Thimble Covers Wall thimble

17

Image 17
Contents QUE Faire SI Vous Sentez UNE Odeur DE GAZ What to do if YOU Smell GASWhat When Information SheetIntroduction Table of ContentsSafety Information Safety InformationINSTALLER’S Information Initial Adjustments Maintenance and Care Parts ListsFire Hazard Service CautionMust be Vented to Outside HOT SurfacesCeramic Fiber LOG Safety Information Specifications Lighting Instructions OWNER’S InformationDaily Operation To Turn OFF GAS to ApplianceCleaning Routine Maintenance and CareCodes INSTALLER’S InformationFIREBOX, PILOT, & Burner Tubes Packing List Items Required for InstallationUnpacking and Inspection Hearth REQUIREMENT/FLOOR ProtectionClearance to Combustibles Champlain Model #8300 Acceptable Direct Vent Termination Cap locations Venting Connection Venting InformationApproved Venting System Components Venting Components & ConfigurationAcceptable Direct Vent Termination CAP Locations Acceptable Venting Lengths DV Class a Chimney Systems Fireplace Venting ConfigurationsDV Chimney CO-LINER System DV Chimney CO-AXIAL Liner SystemFireplace Installation Approved Vertical Termination Venting Configurations with Venting ConfigurationsHorizontal Termination Horizontal Termination Venting ConfigurationsVenting KIT KIT #93-65000 Thermostat Placement Remote ControlThermostat Wiring Electrical ConnectionsElectrical Grounding Instructions Wiring InstructionsBlower FAN Wiring Diagram › Caution Check Gas Type GAS Supply ConnectionsInstallation of the LOG SET LOG PlacementTo Equipment Inlet Nipple Gas Supply TeeFitting MIN Cap Log Set Assembly Lighting the Unit for the First Time AIR Shutter Adjustments Initial AdjustmentsVariable Output Control AIR ShutterBurner Flame Appearance Pilot AdjustmentCleaning › Warning do not Clean the Unit When IT’S HOT Maintenance CareFirebox Pilot & Burner FlamesCleaning the Glass › Warning Parts ListsTroubleshooting Troubleshooting Troubleshooting Fuel Type Rating LabelLimited FIVE-YEAR Warranty Limited Lifetime WarrantyLimited THREE-YEAR Warranty Limited ONE-YEAR WarrantyExclusions Qualifying for Warranty CoverageWarranty Registration