Hearth and Home Technologies 8300 To Equipment Inlet Nipple Gas Supply TeeFitting MIN Cap

Page 29

HearthStone Quality Home Heating Products Inc

Champlain Model #8300

4.Gently place the Middle Log (2) in the firebox against the front of the Rear Log. There are slots on the underside that fit in between the burner tube and into the burner tube holder. The rear tabs on the Middle Log should touch the front of the Rear Log, and the log should be centered as best as possible.

5.Place the Ember Screen (3) on the front of the burner tube with the long side of the Screen on the tube. The short tab should be facing forward on the bottom of the firebox.

6.Gently place the Front Log (4) in the firebox against the front of the burner tube. Center as best as possible.

7.Spread evenly across the Ember Screen, the Charcoal Embers (5).

8.Gently place the Top Log (6) in the firebox on top of the Middle Log. The Middle Log has 2 posts, which slide into the 2 holes on the underside of the Top Log. The “leg” on the Top Log points towards the rear.

9.With logs in place, place the glass and frame back on the firebox. Slide the clips down securing the glass to the firebox.

10.Grasp the cast façade and slide the top edge under the lip of the top castings. Push the bottom of the façade in towards the firebox. While pushing in, pull the latch down to secure the façade to the firebox.

To Equipment

Inlet

Nipple

Gas Supply

Inlet

TeeFitting

3" MIN.

Cap

Sediment Trap

29

Image 29
Contents QUE Faire SI Vous Sentez UNE Odeur DE GAZ What to do if YOU Smell GASWhat When Information SheetIntroduction Table of ContentsSafety Information Safety InformationINSTALLER’S Information Initial Adjustments Maintenance and Care Parts ListsFire Hazard Service CautionMust be Vented to Outside HOT SurfacesCeramic Fiber LOG Safety Information Specifications Lighting Instructions OWNER’S InformationDaily Operation To Turn OFF GAS to ApplianceCleaning Routine Maintenance and CareCodes INSTALLER’S InformationFIREBOX, PILOT, & Burner Tubes Packing List Items Required for InstallationUnpacking and Inspection Hearth REQUIREMENT/FLOOR ProtectionClearance to Combustibles Champlain Model #8300 Acceptable Direct Vent Termination Cap locations Venting Connection Venting InformationApproved Venting System Components Venting Components & ConfigurationAcceptable Direct Vent Termination CAP Locations Acceptable Venting Lengths DV Class a Chimney Systems Fireplace Venting ConfigurationsDV Chimney CO-LINER System DV Chimney CO-AXIAL Liner SystemFireplace Installation Approved Vertical Termination Venting Configurations with Venting ConfigurationsHorizontal Termination Horizontal Termination Venting ConfigurationsVenting KIT KIT #93-65000 Thermostat Placement Remote ControlThermostat Wiring Electrical ConnectionsElectrical Grounding Instructions Wiring InstructionsBlower FAN Wiring Diagram › Caution Check Gas Type GAS Supply ConnectionsInstallation of the LOG SET LOG PlacementTo Equipment Inlet Nipple Gas Supply TeeFitting MIN Cap Log Set Assembly Lighting the Unit for the First Time AIR Shutter Adjustments Initial AdjustmentsVariable Output Control AIR ShutterBurner Flame Appearance Pilot AdjustmentCleaning › Warning do not Clean the Unit When IT’S HOT Maintenance CareFirebox Pilot & Burner FlamesCleaning the Glass › Warning Parts ListsTroubleshooting Troubleshooting Troubleshooting Fuel Type Rating LabelLimited FIVE-YEAR Warranty Limited Lifetime WarrantyLimited THREE-YEAR Warranty Limited ONE-YEAR WarrantyExclusions Qualifying for Warranty CoverageWarranty Registration