VENTING INFORMATION

VENTING CONNECTION

1.The Champlain Direct Vent is approved for installation only with the vent

connecting components listed on this page. Use the following instructions along with the pipe manufacturer’s instructions to complete the installation.

2. Attach the inner starter collar and gasket to the unit with the eight # 8-32 x 3/8" Phillips Head self-tapping screws.

3. Place the outer starter collar and gasket onto the back of the stove. Secure the outer adapter with the eight # 8-32 x 3/8" Phillips Head self-tapping screws that are provided. Install the rest of the

vent system according to the manufacturer’s instructions.

1.

Gasket 4”

3160-130

2.

Inner starter

924H

3.

Gasket 6”

3160-157

4.

Outer Starter

924H

Figure 7: Gasket & Stove Adapter Installation

16

Image 16
Contents What to do if YOU Smell GAS QUE Faire SI Vous Sentez UNE Odeur DE GAZInformation Sheet What WhenTable of Contents IntroductionSafety Information Safety InformationINSTALLER’S Information Initial Adjustments Maintenance and Care Parts ListsService Caution Fire HazardMust be Vented to Outside HOT SurfacesCeramic Fiber LOG Safety Information Specifications OWNER’S Information Lighting InstructionsTo Turn OFF GAS to Appliance Daily OperationRoutine Maintenance and Care CleaningFIREBOX, PILOT, & Burner Tubes INSTALLER’S InformationCodes Items Required for Installation Packing ListUnpacking and Inspection Hearth REQUIREMENT/FLOOR ProtectionClearance to Combustibles Champlain Model #8300 Acceptable Direct Vent Termination Cap locations Venting Information Venting ConnectionAcceptable Direct Vent Termination CAP Locations Venting Components & ConfigurationApproved Venting System Components Acceptable Venting Lengths Fireplace Venting Configurations DV Class a Chimney SystemsDV Chimney CO-LINER System DV Chimney CO-AXIAL Liner SystemFireplace Installation Venting Configurations Approved Vertical Termination Venting Configurations withHorizontal Termination Venting Configurations Horizontal TerminationVenting KIT KIT #93-65000 Remote Control Thermostat PlacementThermostat Wiring Electrical ConnectionsBlower FAN Wiring InstructionsElectrical Grounding Instructions Wiring Diagram GAS Supply Connections › Caution Check Gas TypeLOG Placement Installation of the LOG SETTo Equipment Inlet Nipple Gas Supply TeeFitting MIN Cap Log Set Assembly Lighting the Unit for the First Time Initial Adjustments AIR Shutter AdjustmentsVariable Output Control AIR ShutterPilot Adjustment Burner Flame AppearanceMaintenance Care Cleaning › Warning do not Clean the Unit When IT’S HOTFirebox Pilot & Burner FlamesCleaning the Glass Parts Lists › WarningTroubleshooting Troubleshooting Troubleshooting Rating Label Fuel TypeLimited Lifetime Warranty Limited FIVE-YEAR WarrantyLimited THREE-YEAR Warranty Limited ONE-YEAR WarrantyQualifying for Warranty Coverage ExclusionsWarranty Registration