Hearth and Home Technologies 8300 owner manual Specifications

Page 7

HearthStone Quality Home Heating Products Inc

Champlain Model #8300

SPECIFICATIONS:

LISTED: DIRECT VENT GAS HEATER

Listed: DV Gas Heater

Model: Champlain DV Room Heater

Testing Agency: Intertek Testing Services NA Inc. (ITS)

Tested to: ANSI Z21.88-1998, CSA 2.33-M98, CAN/CGA2.17

Figure 1: Champlain Dimensions

 

NG

LP

Input rating (Btu/hr) 0-2000ft

37,000

37,000

Maximum output (Btu/hr) 0-2000ft

26,200

26,800

Minimum input rating (Btu/hr)

20,300

22,600

Orifice size DMS 0-2000ft

31

49

Man. pressure- HI setting (in.w.c./kPa)

3.5/0.84 10.0/2.48

Man. pressure- LO setting (in.w.c./kPa)

1.2/0.30

3.3/0.80

Inlet pressure-HI (in.w.c./kPa.)

7.0/1.74 13.0/3.22

Inlet pressure-Lo (in.w.c./kPa)

5.0/1.24 11.0/2.75

7

Image 7
Contents QUE Faire SI Vous Sentez UNE Odeur DE GAZ What to do if YOU Smell GASWhat When Information SheetIntroduction Table of ContentsInitial Adjustments Maintenance and Care Parts Lists Safety InformationSafety Information INSTALLER’S InformationHOT Surfaces Service CautionFire Hazard Must be Vented to OutsideCeramic Fiber LOG Safety Information Specifications Lighting Instructions OWNER’S InformationDaily Operation To Turn OFF GAS to ApplianceCleaning Routine Maintenance and CareFIREBOX, PILOT, & Burner Tubes INSTALLER’S InformationCodes Hearth REQUIREMENT/FLOOR Protection Items Required for InstallationPacking List Unpacking and InspectionClearance to Combustibles Champlain Model #8300 Acceptable Direct Vent Termination Cap locations Venting Connection Venting InformationAcceptable Direct Vent Termination CAP Locations Venting Components & ConfigurationApproved Venting System Components Acceptable Venting Lengths DV Chimney CO-AXIAL Liner System Fireplace Venting ConfigurationsDV Class a Chimney Systems DV Chimney CO-LINER SystemFireplace Installation Approved Vertical Termination Venting Configurations with Venting ConfigurationsHorizontal Termination Horizontal Termination Venting ConfigurationsVenting KIT KIT #93-65000 Electrical Connections Remote ControlThermostat Placement Thermostat WiringBlower FAN Wiring InstructionsElectrical Grounding Instructions Wiring Diagram › Caution Check Gas Type GAS Supply ConnectionsInstallation of the LOG SET LOG PlacementTo Equipment Inlet Nipple Gas Supply TeeFitting MIN Cap Log Set Assembly Lighting the Unit for the First Time AIR Shutter Initial AdjustmentsAIR Shutter Adjustments Variable Output ControlBurner Flame Appearance Pilot AdjustmentPilot & Burner Flames Maintenance CareCleaning › Warning do not Clean the Unit When IT’S HOT FireboxCleaning the Glass › Warning Parts ListsTroubleshooting Troubleshooting Troubleshooting Fuel Type Rating LabelLimited ONE-YEAR Warranty Limited Lifetime WarrantyLimited FIVE-YEAR Warranty Limited THREE-YEAR WarrantyExclusions Qualifying for Warranty CoverageWarranty Registration