Hearth and Home Technologies 8300 owner manual Electrical Connections, Thermostat, Remote Control

Page 24

HearthStone Quality Home Heating Products Inc

Champlain Model #8300

Conditionally approved for purchased mobile home installation. This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used, available through your local HearthStone dealer.

Cet appareil peut être installé dans un maison préfabriquée (mobile) déjà installée

àdemeure si les règlements locaux le permettent.

Cet appareil doit être utilisé uniquement avec les types de gas indiqués sur la plaque signalétique. Ne pas l’utiliser avec d’autres gas sauf si un kitde conversion certifié est installé.

ELECTRICAL CONNECTIONS

NOTE: OPEN VALVE DOOR ON THE FRONT FOR ELECTRICAL AND GAS CONNECTIONS.

THERMOSTAT

The ON/OFF/T-STAT switch or wall mounted thermostat controls the Champlain. We recommend installation of the

thermostat for more comfortable performance, however you may still override the thermostat by setting the switch to “ON”. The thermostat controls the unit by “calling for heat.” The thermostat turns the unit on when the room is cold, and turns the unit off once the room is warmed sufficiently. The thermostat is controlled by a 750 millivolt DC two-wire circuit.

REMOTE CONTROL

There are two different optional remote controls. Both of the remote controls are capable of turning the unit on and off. One of the optional remotes also allows you to control the temperature of the stove, (in the same way the thermostat controls the heater), from anywhere in the vicinity of the unit. If “ON” & “OFF” are the only controls required, Kit #90-56912 can be used. If you would like to control the temperature via the remote control, use Kit #90-56914. Installation instructions are provided with the kits.

THERMOSTAT PLACEMENT

The thermostat should be placed in the same room or living space as the unit. Typically 5’ (1.5m) off the floor and away from any influences that may cause the temperature in the vicinity of the thermostat to be unrepresentative of the room temperature in general. Such influences might include strong lighting, a heater vent from the central heating system, or a nearby drafty window.

Placement of the thermostat on an inside wall rather than an outside wall is preferable. Do not place the thermostat directly behind or too close to the unit, otherwise heat from the unit will immediately satisfy the thermostat and turn the unit off.

THERMOSTAT WIRING

The thermostat wire from the unit to the thermostat can be surface mounted, routed under the floor, or through walls, etc. The thermostat should be connected to the unit using a maximum of 40’ (12m) of insulated thermostat wire (minimum of 18 Ga.) When making these connections, position the

24

Image 24
Contents What to do if YOU Smell GAS QUE Faire SI Vous Sentez UNE Odeur DE GAZInformation Sheet What WhenTable of Contents IntroductionSafety Information Safety InformationINSTALLER’S Information Initial Adjustments Maintenance and Care Parts ListsService Caution Fire HazardMust be Vented to Outside HOT SurfacesCeramic Fiber LOG Safety Information Specifications OWNER’S Information Lighting InstructionsTo Turn OFF GAS to Appliance Daily OperationRoutine Maintenance and Care CleaningINSTALLER’S Information FIREBOX, PILOT, & Burner TubesCodes Items Required for Installation Packing ListUnpacking and Inspection Hearth REQUIREMENT/FLOOR ProtectionClearance to Combustibles Champlain Model #8300 Acceptable Direct Vent Termination Cap locations Venting Information Venting ConnectionVenting Components & Configuration Acceptable Direct Vent Termination CAP LocationsApproved Venting System Components Acceptable Venting Lengths Fireplace Venting Configurations DV Class a Chimney SystemsDV Chimney CO-LINER System DV Chimney CO-AXIAL Liner SystemFireplace Installation Venting Configurations Approved Vertical Termination Venting Configurations withHorizontal Termination Venting Configurations Horizontal TerminationVenting KIT KIT #93-65000 Remote Control Thermostat PlacementThermostat Wiring Electrical ConnectionsWiring Instructions Blower FANElectrical Grounding Instructions Wiring Diagram GAS Supply Connections › Caution Check Gas TypeLOG Placement Installation of the LOG SETTo Equipment Inlet Nipple Gas Supply TeeFitting MIN Cap Log Set Assembly Lighting the Unit for the First Time Initial Adjustments AIR Shutter AdjustmentsVariable Output Control AIR ShutterPilot Adjustment Burner Flame AppearanceMaintenance Care Cleaning › Warning do not Clean the Unit When IT’S HOTFirebox Pilot & Burner FlamesCleaning the Glass Parts Lists › WarningTroubleshooting Troubleshooting Troubleshooting Rating Label Fuel TypeLimited Lifetime Warranty Limited FIVE-YEAR WarrantyLimited THREE-YEAR Warranty Limited ONE-YEAR WarrantyQualifying for Warranty Coverage ExclusionsWarranty Registration