Hearth and Home Technologies 8300 owner manual Venting Configurations

Page 21

HearthStone Quality Home Heating Products Inc

Champlain Model #8300

VENTING CONFIGURATIONS

-2’ minimum system height (with or without offsets)

-30’ maximum system height (with or without offsets – note shutter setting)

-10’ maximum offset (refer to Figures 8, 9, & 11 – note shutter setting)

-maximum rise to run = 1 to 5 (refer to Figures 8 & 9 – note shutter setting)

-The termination must fall within the area outlined by the shaded area shown in Figure 8 and the Chart in Figure 9 should be considered as well.

Figure 11: Vertical Termination

APPROVED VERTICAL TERMINATION VENTING CONFIGURATIONS WITH:

1.

Two 90º Elbows

2.

Two 45º Elbows

3.

No Elbows

90º Elbow

45º Elbow

Straight Pipe

Straight Pipe

Straight Pipe

 

 

21

Image 21
Contents QUE Faire SI Vous Sentez UNE Odeur DE GAZ What to do if YOU Smell GASWhat When Information SheetIntroduction Table of ContentsSafety Information Safety InformationINSTALLER’S Information Initial Adjustments Maintenance and Care Parts ListsFire Hazard Service CautionMust be Vented to Outside HOT SurfacesCeramic Fiber LOG Safety Information Specifications Lighting Instructions OWNER’S InformationDaily Operation To Turn OFF GAS to ApplianceCleaning Routine Maintenance and CareINSTALLER’S Information FIREBOX, PILOT, & Burner TubesCodes Packing List Items Required for InstallationUnpacking and Inspection Hearth REQUIREMENT/FLOOR ProtectionClearance to Combustibles Champlain Model #8300 Acceptable Direct Vent Termination Cap locations Venting Connection Venting InformationVenting Components & Configuration Acceptable Direct Vent Termination CAP LocationsApproved Venting System Components Acceptable Venting Lengths DV Class a Chimney Systems Fireplace Venting ConfigurationsDV Chimney CO-LINER System DV Chimney CO-AXIAL Liner SystemFireplace Installation Approved Vertical Termination Venting Configurations with Venting ConfigurationsHorizontal Termination Horizontal Termination Venting ConfigurationsVenting KIT KIT #93-65000 Thermostat Placement Remote ControlThermostat Wiring Electrical ConnectionsWiring Instructions Blower FANElectrical Grounding Instructions Wiring Diagram › Caution Check Gas Type GAS Supply ConnectionsInstallation of the LOG SET LOG PlacementTo Equipment Inlet Nipple Gas Supply TeeFitting MIN Cap Log Set Assembly Lighting the Unit for the First Time AIR Shutter Adjustments Initial AdjustmentsVariable Output Control AIR ShutterBurner Flame Appearance Pilot AdjustmentCleaning › Warning do not Clean the Unit When IT’S HOT Maintenance CareFirebox Pilot & Burner FlamesCleaning the Glass › Warning Parts ListsTroubleshooting Troubleshooting Troubleshooting Fuel Type Rating LabelLimited FIVE-YEAR Warranty Limited Lifetime WarrantyLimited THREE-YEAR Warranty Limited ONE-YEAR WarrantyExclusions Qualifying for Warranty CoverageWarranty Registration