HearthStone Quality Home Heating Products Inc | Champlain Model #8300 |
HORIZONTAL TERMINATION VENTING CONFIGURATIONS
-A minimum of 2’ rise is required (with or without offsets)
-30’ maximum system height (with or without offsets – note shutter setting)
-10’ maximum offset (refer to Figures 8, 9, & 12 – note shutter setting)
-maximum rise to run = 1 to 5 (refer to Figures 8 & 9 – note shutter setting)
-The termination must fall within the area outlined by the shaded area shown in Figure 8 and the Chart in Figure 9 should be considered as well.
-Use a vinyl siding stand off when installing against a vinyl siding.
-Horizontal sections require a ¼” rise every 12” of horizontal run.
-For each 90º elbow after the second, remove 5’ from horizontal run.
-At minimum vertical rise, maximum horizontal run is 10’
-Use with snorkel termination 10’ maximum horizontal run.
Approved DV Venting Configuration for
Horizontal Termination with:
1. (1) 90º Elbow & (1) 45º Elbow
∙ 90º Elbow
∙ 45º Elbow
∙ Straight Pipe
2. (1) 90º Elbow
∙ 90º Elbow
∙ Straight Pipe
3. (2) 90º Elbow
∙ (2) 90º Elbows
∙ Straight Pipe
4. Snorkel
∙ Snorkel (3 foot) ∙ Straight Pipe
Figure 12. Horizontal Termination
22