HearthStone Quality Home Heating Products Inc

Champlain Model #8300

INTRODUCTION

Congratulations on your purchase of a Champlain Gas-Fired Direct Vent heater. The Champlain, by HearthStone Cast Iron Stoves, incorporates the latest in balanced vent gas technology, which will provide you with clean, efficient heat for years to come.

The Champlain will provide you with years of practical and convenient service. However, as with any gas appliance, the unit must be properly and safely installed and maintained by qualified service personnel to ensure safe and trouble-free operation.

Your Champlain is equipped with a standard pilot which:

1.generates a milli-volt signal that powers the wall-mounted thermostat and;

2.lights the main burner when the thermostat calls for heat.

This unit is equipped with an On/Off/Thermostat switch and a variable output control. The variable output control is located on the gas control valve. It allows you to vary the heat output, along with the flame height to suit personal taste. Heat output can be reduced {set to “LOW”} during the Fall and Spring, when the need for heat is reduced and increased {set to “HIGH” during Winter months, when the need for heat is the greatest.

A wall-mounted thermostat is provided by HearthStone. Regardless of how you set the variable output control, when the optional thermostat has been installed and the On/Off/Thermostat switch is set to “Thermostat”, the wall-mounted thermostat will control the on/off cycling of the unit. At any time, you can override the thermostat

with the On/Off/Thermostat switch by setting it to “ON” or “OFF”.

The Unit can also be equipped with an optional blower fan, which turns on and off independently of the burner flames. When the speed switch, which allows you to turn the fan on or off and control the speed of the fan to suit your needs, is set to “On”, the fan will automatically turn on when the stove is hot and cycle off when the unit is no longer hot.

Also available are two different optional remote controls. Both of the remote controls are capable of turning the unit on and off. One of the optional remotes also allows you to control the temperature of the stove from anywhere in the vicinity of the unit. If “ON”

&“OFF” are the only controls required, Kit

# 90-56912 can be used. If you would like to control the temperature via the remote control, use Kit # 90-56914.

READ THIS OWNERS MANUAL

Operate and maintain this gas heater according to the instructions in this manual.

Read this manual in its entirety. This manual has two sections, the first section is for the OPERATOR, and the second section is

for the QUALIFIED SERVICE PERSONNEL only.

HEATER MUST BE INSTALLED

AND MAINTAINED BY QUALIFIED

SERVICE PERSONNEL

Verify the gas connections and venting systems with requirements of local, regional

or national installation codes. Qualified service personnel must inspect the gas heater before use and at least annually.

TABLE OF CONTENTS

READ THIS OWNER’S MANUAL........ 1

3

Image 3
Contents QUE Faire SI Vous Sentez UNE Odeur DE GAZ What to do if YOU Smell GASWhat When Information SheetIntroduction Table of ContentsInitial Adjustments Maintenance and Care Parts Lists Safety InformationSafety Information INSTALLER’S InformationHOT Surfaces Service CautionFire Hazard Must be Vented to OutsideCeramic Fiber LOG Safety Information Specifications Lighting Instructions OWNER’S InformationDaily Operation To Turn OFF GAS to ApplianceCleaning Routine Maintenance and CareINSTALLER’S Information FIREBOX, PILOT, & Burner TubesCodes Hearth REQUIREMENT/FLOOR Protection Items Required for InstallationPacking List Unpacking and InspectionClearance to Combustibles Champlain Model #8300 Acceptable Direct Vent Termination Cap locations Venting Connection Venting InformationVenting Components & Configuration Acceptable Direct Vent Termination CAP LocationsApproved Venting System Components Acceptable Venting Lengths DV Chimney CO-AXIAL Liner System Fireplace Venting ConfigurationsDV Class a Chimney Systems DV Chimney CO-LINER SystemFireplace Installation Approved Vertical Termination Venting Configurations with Venting ConfigurationsHorizontal Termination Horizontal Termination Venting ConfigurationsVenting KIT KIT #93-65000 Electrical Connections Remote ControlThermostat Placement Thermostat WiringWiring Instructions Blower FANElectrical Grounding Instructions Wiring Diagram › Caution Check Gas Type GAS Supply ConnectionsInstallation of the LOG SET LOG PlacementTo Equipment Inlet Nipple Gas Supply TeeFitting MIN Cap Log Set Assembly Lighting the Unit for the First Time AIR Shutter Initial AdjustmentsAIR Shutter Adjustments Variable Output ControlBurner Flame Appearance Pilot AdjustmentPilot & Burner Flames Maintenance CareCleaning › Warning do not Clean the Unit When IT’S HOT FireboxCleaning the Glass › Warning Parts ListsTroubleshooting Troubleshooting Troubleshooting Fuel Type Rating LabelLimited ONE-YEAR Warranty Limited Lifetime WarrantyLimited FIVE-YEAR Warranty Limited THREE-YEAR WarrantyExclusions Qualifying for Warranty CoverageWarranty Registration