Hearth and Home Technologies 8300 owner manual Troubleshooting

Page 38

HearthStone Quality Home Heating Products Inc

CHAMPLAIN Gas-Fired Direct Vent

TROUBLESHOOTING

 

 

 

 

 

Symptom

Possible Cause

Corrective Action

 

3. Pilot burning, no

A. Thermostat switch or

A. Check thermostat/wiring for proper

 

gas to main burner,

wires defective.

connections. Place jumper wire across

 

valve knob in the

 

terminals at thermostat. If burner comes on,

 

"ON" position,

 

replace defective thermostat. If not OK, place

 

thermostat and/or

 

jumper across thermostat wires at gas valve.

 

on/off/t'stat switch

 

If burner comes on, tighten connections, or

 

in the "ON"

 

replace faulty wires.

 

position.

 

 

 

 

 

 

 

 

B. Thermopile may not be

 

 

 

generating sufficient voltage.

B. Check thermopile output, using a milli-volt

 

 

 

meter. If the optional on/off kit has not been

 

 

 

installed, take the readings across generator

 

 

 

terminals of the gas valve. TPTH and TP).

 

 

 

With the on/off kit, take the readings across

 

 

 

TH and Terminal block (which corresponds to

 

 

 

#3 on the switch). Milli-volt reading should be

 

 

 

greater than 325 mV. If not, replace the pilot

 

 

 

assembly. If the meter reading is OK, but the

 

 

 

burner does not come on, replace the gas

 

 

 

valve.

 

 

C. Plugged burner orifice.

C. Remove and check burner orifice, clean or

 

 

 

replace. Note: do not use any metal cleaning

 

 

 

device, as this may damage the orifice.

 

 

 

 

 

4. Pilot and burner

A. Inconsistent, of

A. Adjust pilot flame size and assure that the

 

insufficient flame on

flame is aimed directly at the thermopile.

 

come on, but go

 

thermopile.

 

 

out after some

 

 

 

 

 

warm-up.

 

 

 

 

B. Insufficient gas pressure.

B. Check line pressure to ensure that the

 

 

 

correct inlet pressure is present for the type

 

 

 

of gas being used. If propane pressure is

 

 

 

inconsistent, check for water condensation at

 

 

 

the regulator.

 

 

 

 

 

5. Frequent pilot

A. Pilot flame may be too

A. Clean and/or adjust the pilot flame for

 

outrage problem.

low or blowing, (high),

maximum impingement on the thermopile

 

 

causing the pilot safety to

and thermocouple.

 

 

drop out.

 

 

 

 

 

 

6. Glass fogs

A. A normal result of gas

A. After the heater has warmed up, the glass

 

 

combustion.

 

 

should clear.

 

 

 

 

7. Blue Flames

A. A normal result during the

A. Flames should begin to turn more

 

 

first 20 minutes.

yellowish after 20 minutes of burning.

 

 

 

 

 

 

B. If the blue color stays; adjust the air

 

 

 

shutter for a proper burn.

 

38

Image 38
Contents What to do if YOU Smell GAS QUE Faire SI Vous Sentez UNE Odeur DE GAZInformation Sheet What WhenTable of Contents IntroductionINSTALLER’S Information Safety InformationSafety Information Initial Adjustments Maintenance and Care Parts ListsMust be Vented to Outside Service CautionFire Hazard HOT SurfacesCeramic Fiber LOG Safety Information Specifications OWNER’S Information Lighting InstructionsTo Turn OFF GAS to Appliance Daily OperationRoutine Maintenance and Care CleaningCodes INSTALLER’S InformationFIREBOX, PILOT, & Burner Tubes Unpacking and Inspection Items Required for InstallationPacking List Hearth REQUIREMENT/FLOOR ProtectionClearance to Combustibles Champlain Model #8300 Acceptable Direct Vent Termination Cap locations Venting Information Venting ConnectionApproved Venting System Components Venting Components & ConfigurationAcceptable Direct Vent Termination CAP Locations Acceptable Venting Lengths DV Chimney CO-LINER System Fireplace Venting ConfigurationsDV Class a Chimney Systems DV Chimney CO-AXIAL Liner SystemFireplace Installation Venting Configurations Approved Vertical Termination Venting Configurations withHorizontal Termination Venting Configurations Horizontal TerminationVenting KIT KIT #93-65000 Thermostat Wiring Remote ControlThermostat Placement Electrical ConnectionsElectrical Grounding Instructions Wiring InstructionsBlower FAN Wiring Diagram GAS Supply Connections › Caution Check Gas TypeLOG Placement Installation of the LOG SETTo Equipment Inlet Nipple Gas Supply TeeFitting MIN Cap Log Set Assembly Lighting the Unit for the First Time Variable Output Control Initial AdjustmentsAIR Shutter Adjustments AIR ShutterPilot Adjustment Burner Flame AppearanceFirebox Maintenance CareCleaning › Warning do not Clean the Unit When IT’S HOT Pilot & Burner FlamesCleaning the Glass Parts Lists › WarningTroubleshooting Troubleshooting Troubleshooting Rating Label Fuel TypeLimited THREE-YEAR Warranty Limited Lifetime WarrantyLimited FIVE-YEAR Warranty Limited ONE-YEAR WarrantyQualifying for Warranty Coverage ExclusionsWarranty Registration