10 Electrical Information
A. Electronic Ignition System Wiring
•This gas appliance is equipped with an electronic ignition system which operates on a 6 volt system.
•The batteries are located within the ignition module which is located under the unit. A wiring diagram is shown in Figure 7.1.
•The battery pack requires four AA batteries (not included).
CAUTION
Battery polarity must be correct or module damage will occur.
WARNING
Shock hazard.
•Replace damaged wire with type 105º C rated wire.
•Wire must have high temperature insulation.
CAUTION
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
| FLAME SPARKER/ |
|
| SENSOR | VALVE |
| PILOT |
|
| IGNITION MODULE | REMOTE |
| CONTROL | |
| 6VDC | ANT. |
|
| ON/OFF |
|
| WALL SWITCH |
|
| IGNITION |
|
| MODULE |
|
| (6V) |
| BATTERY PORT |
|
| (4 AA BATTERIES) |
|
|
| THERMOCOUPLE |
|
| BLOCK |
| ON/OFF | (CONNECTED TO |
| BACK OF VALVE) | |
| SWITCH | |
|
| |
|
| VALVE |
| PILOT GAS LINE |
|
| CONNECTED TO |
|
| BACK OF VALVE |
|
Figure 10.1 | Electronic Ignition Wiring Diagram |
|
| Heat & Glo • | 23 |