Concentric | Vent Sidewall |
|
Attachment |
|
|
Strap |
|
|
(Field Supplied) | _,_////_ | Combustion |
| \ Air |
|
Vent
Combustion | _ _ | _///,//_ |
Air | 45° Elbow | _/////_ |
| (Field Supplied) |
|
Note:
Securing strap mustbefieldinstalledto prevent movementofterminationkit in sidewall.
8.Install the rain cap and the small diameter pipe assembly in the Y concentric fitting and the large pipe assembly. Ensure that the small diameter pipe is bottomed out and securely cemented in the Y concentric fitting.
9.Cement the furnace combustion air and vent pipes to the
concentric vent termination assembly. See Figure 45 or Figure 49 for proper pipe attachment.
10.Operate the furnace through one heat cycle to ensure com-
bustion air and vent pipes are properly connected to the concentric termination connections.