Goodman Mfg TSTATG2111 owner manual Setting the Fan-Off Time Delay, 003

Page 32

Air Conditioning & Heating

Setting the Fan-Off Time Delay

To increase the cooling efficiency of your unit, the thermostat may be programmed to continue running the fan after a call for cooling has been satisfied. This delay may be set for 30, 60, or 90 seconds. If the Fan Off Delay is set for zero seconds, the fan will not energize after a call for cooling has been satisfied.

7

MODE

Press SETUP button to enter Setup screens.

Press the MODE button repeatedly until this setup screen appears.

Note: Press the MODE button momentarily to move through the setup screens. Press and hold the MODE button to move back- wards through the setup screens.

Set the Fan Off Delay to 0, 30, 60, or 90 seconds.

Setup

:003

FanOn

Press

Press the PROGRAM button to leave the Setup screens. If no buttons are pressed, the display will leave the setup screens after 30 seconds.

Page 7.3

Image 32
Contents Owner’ ’sManual l 4Z95 How to Use This Manual Glossary of Terms Table of Contents Contents Heat Front PanelDisplay Features CoolService Filter icon Section Selecting Your Desired Setting the Clock Selecting the Heat or CoolUsing the Fan Button Setting the Clock 1200 AmSelecting the Heat or Cool Mode Select Mode by Pressing the Mode ButtonSelecting Your Desired Temperature adjusting the setpoints Auto or Program ModeSetting the Clock Setting the Clock Contents Press Setup button to enter Setup screens Programmable or Non-Programmable ThermostatManual or Auto-Changeover Thermostat Operating Mode when the Thermostat is Configured to be Cooling Only Time Schedule for Programmable with Auto-Changeover If the thermostat is Selecting Your Desired Temperature adjusting setpoints Viewing the Outdoor Temperature Viewing the Outdoor Temperature Programming a Daily ScheduleProgramming a Daily Schedule 600800 1000 Using the Fan Button Setting the Fan-Off Time DelayUsing the Fan Button Setting the Fan-Off Time Delay 003Contents Turning On/Off the Backlight Locking/Unlocking the Keypad 1200Programming Run-Time Alerts How to Set and Reset the Service Filter Fan Run-Time Alert How to Set and Reset the UV Light Run-Time Alert Until this setup screen appearsElectric Heat and Heat Pump Operation Viewing the Heat Pump Reversing Valve Jumper Settings Viewing the Electric Heat Jumper Setting Using Emergency Heat Adjusting the Deadband 11.4 11.3Adjusting the Heat/Cool Differential Adjusting the Cycles Per Hour Adjusting the Deadband Adjust the deadband for the 1st stage 12.3 Calibrating the Temperature and Humidity Sensors 1200 PmAccessories Advanced Setup Index Heat Manual Time Schedule 88-746 Rev Resetting the Thermostat to Factory Default Settings for default values see