Air Conditioning & Heating
Viewing the Heat Pump and
Reversing Valve Jumper Settings
Steps 10 and 11 are ‘Read Only’ and may only be set with the jumpers on the circuit board of the thermostat (see page 4.4 of the Installation Instructions).
MODE
Press SETUP button to enter Setup screens.
Press the MODE button repeatedly until this setup screen appears.
Note: Press the MODE button momentarily to move through the setup screens. Press and hold the MODE button to move back- wards through the setup screens.
10
ON = Heat Pump
operation
OFF = Gas Electric
operation
Setup
10
OFF HP
Press
Indicates that the thermostat jumper is set for an O
reversing valve (energize in cooling) or a b reversing valve (energize in heating).
Setup
11
O
MODE
Press
Press the PROGRAM button to leave the Setup screens. If no buttons are pressed, the display will leave the setup screens after 30 seconds.
Page 10.2