Air Conditioning & Heating
Adjusting the Cycles Per Hour
The Cycles Per Hour setting may limit the number of times per hour your HVAC unit may energize. For example, at a setting of 6 cycles per hour the HVAC unit will only be allowed to energize once every 10 minutes. The Cycles Per Hour limit may be overridden and reset by pressing the UP or DOWN buttons on the thermostat.
MODE
Press SETUP button to enter Setup screens.
Press the MODE button repeatedly until this setup screen appears.
Note: Press the MODE button momentarily to move through the setup screens. Press and hold the MODE button to move back- wards through the setup screens.
| Setup |
Select the cycles per | 14 |
hour limit. | |
d=cycles per hour |
|
limit defeated. |
|
d1=d + defeat 5 min. | Press |
compressor lockout. | |
(d1, d, 2 - 6) | 6 CY |
Press the SETUP button to leave the Setup screens. If no buttons are pressed, the display will leave the setup screens after 30 seconds.
11
Page 11.3