Goodman Mfg TSTATG2111 owner manual Display Features, Cool

Page 8

Air Conditioning & Heating

1

Display Features

 

Am Program On Setup

 

18:88 Pm StartStop

HI 88

 

Service Filter

 

Pan UV Light

COOL

 

AUTO

Outside

 

OFFON

88

 

FanOn188

 

Morning

AUXHEAT

 

DayNight

LO

 

Evening

 

Mode Indicators - Section 4

Selects the operational mode of the equipment. HEAT - Indicates the heating mode.

COOL - Indicates the air conditioning mode.

AUTO - Indicates the system will automatically changeover between heat and cool modes as the temperature varies.

OFF - Indicates heating and cooling is turned off.

PROGRAM ON - Indicates the time period program is enabled to run.

Clock - Section 3

Indicates the current time. This clock is also used to program the time period schedule.

Room Temperature Display - Section 5

Indicates the current room temperature and displays the outdoor temperature when selected.

Desired Set Temperature - Section 4/5 Indicates desired room temperature(s).

Outside icon - Section 5

Indicates the temperature displayed is from the optional outdoor sensor.

Morning, Day, Evening & Night icons - Section 6 Indicates the day part of the time period program.

Page 1.3

Image 8
Contents Owner’ ’sManual l 4Z95 How to Use This Manual Glossary of Terms Table of Contents Contents Heat Front PanelDisplay Features CoolService Filter icon Section Selecting Your Desired Setting the Clock Selecting the Heat or CoolUsing the Fan Button Setting the Clock 1200 AmSelecting the Heat or Cool Mode Select Mode by Pressing the Mode ButtonSelecting Your Desired Temperature adjusting the setpoints Auto or Program ModeSetting the Clock Setting the Clock Contents Press Setup button to enter Setup screens Programmable or Non-Programmable ThermostatManual or Auto-Changeover Thermostat Operating Mode when the Thermostat is Configured to be Cooling Only Time Schedule for Programmable with Auto-Changeover If the thermostat is Selecting Your Desired Temperature adjusting setpoints Viewing the Outdoor Temperature Viewing the Outdoor Temperature Programming a Daily ScheduleProgramming a Daily Schedule 600800 1000 Using the Fan Button Setting the Fan-Off Time DelayUsing the Fan Button Setting the Fan-Off Time Delay 003Contents Turning On/Off the Backlight Locking/Unlocking the Keypad 1200Programming Run-Time Alerts How to Set and Reset the Service Filter Fan Run-Time Alert How to Set and Reset the UV Light Run-Time Alert Until this setup screen appearsElectric Heat and Heat Pump Operation Viewing the Heat Pump Reversing Valve Jumper Settings Viewing the Electric Heat Jumper Setting Using Emergency Heat Adjusting the Deadband 11.4 11.3Adjusting the Heat/Cool Differential Adjusting the Cycles Per Hour Adjusting the Deadband Adjust the deadband for the 1st stage 12.3 Calibrating the Temperature and Humidity Sensors 1200 PmAccessories Advanced Setup Index Heat Manual Time Schedule 88-746 Rev Resetting the Thermostat to Factory Default Settings for default values see