R
CB 1200 Pellet Stove
7Appliance Set-Up
A. Outside Air Kit Instructions
Included in Kit: 1 piece of 2 inch x 3 foot flex hose, 2 hose clamps, 1 collar assembly, termination cap assembly, 1 trim ring, 12 screws.
Tools Needed: Phillips head screw driver; wire cutters; hole saw or jig saw.
1.Rear Installation
2.Floor Installation
a.Remove rear screen and set aside.
b.Install cover plate over hole in right rear floor.
c.Cut a 2 inch minimum hole in the floor to accommodate flex hose.
d.Attach hose to termination cap.
e.Place rope under pedestal to close off air leaks.
a.Measure distance from floor to air vent opening in appli- ance and mark location on wall.
Use saw to cut opening in wall. Cut a
b.Use hose clamp to secure flex pipe to collar assembly.
c.Slide trim ring over flex pipe and run pipe through wall.
d.Attach hose to outside termination cap with second hose clamp.
e.Secure termination cap to outside surface.
f.Secure trim ring to interior wall.
g.Snip corners and remove plate. Figure 17.1.
Screen |
Install Cover Plate |
Seal Pedestal with 26 in. Rope |
Figure 17.3
h.Align and secure collar assembly with 2 of the 4 holes as shown. Figure 17.2.
Snip Corners and remove plate
Figure 17.1
Secure Collar
NO
NO
Figure 17.2
CAUTION
Never draw outside combustion air from:
•Wall, floor or ceiling cavity
•Enclosed space such as an attic or garage
Termination
Cap Assembly
Hose Clamp |
Trim Ring
Flex Hose
Hose Clamp
Collar Assembly
Figure 17.4
September 1, 2008 | Page 17 |