R
CB 1200 Pellet Stove
and Welcome to the Quadra-Fire Family!
Hearth & Home Technologies welcomes you to our tradi- tion of excellence! In choosing a
This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs. Our Research and Development facility then employs the world’s most advanced technology to achieve the optimum operation
of our stoves, inserts and fireplaces. And yet we are old- fashioned when it comes to craftsmanship. Each unit is meticulously fabricated and surfaces are
We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance. Thank you for choosing
SAMPLE SERIAL NUMBER / SAFETY LABEL LOCATION:
Behind left side curtain on outside of hopper wall.
CAUTION: HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS. Operate this unit with fuel hopper lid closed. Failure to do so may result in emissions products' combustion from the hopper under certain conditions. Maintain hopper seal in good condition. Do no over fill the hopper.
ATTENTION: CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES BRÛLURES À LA PEAU. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS. Opérez cet appareil avec le couvercle de la trémie fermé. Le défaut de ne pas suivre les instructions peut résulter, sous certaines conditions, en une combustion des émissions des produits venant de la trémie. Ne pas remplir la trémie trop pleine.
|
|
|
|
|
|
|
|
|
|
|
| |
| Tested and | Portland | Report / Rapport |
|
|
| SERIAL NO. / NUMÉRO DU |
|
| |||
| Listed by | Oregon USA |
|
| CB 1200 Pellet Stove | 007C |
|
| ||||
|
| C | US |
|
|
|
| |||||
| Installation. This appliance has |
|
|
|
|
|
| |||||
|
| Appareil de chauffage inséré de combustible solide/de type de boulettes. Accepté dans l'installation dans les maisons mobiles. Cet | ||||||||||
Listed Solid Fuel Room Heater/Pellet Type Insert. Also suitable for Mobile Home | ||||||||||||
been tested and listed for use in Manufactured Homes in accordance with OAR | appareil a été testé et enregistré pour l'usage dans les Maisons Mobiles en accord avec OAR | |||||||||||
Tested to: ASTM | Testé à: ASTM |
| ||||||||||
| ||||||||||||
APFI, (UM) |
| |||||||||||
Input Rating: 40,000 Btu's/hr |
|
|
| Puissance de Rendement: 40,000 Btu's/hr |
|
|
|
| ||||
|
|
|
|
|
|
| ||||||
Electrical Rating: 115 VAC, 60 Hz, Start 4.6 Amps, Run 1.6 AMPS. | Puissance Électrique: 115 VAC, 60 Hz, Début 4.6 Amps, Courir 1.6 Amps, |
|
|
|
| |||||||
Route power cord away from unit. Do not route cord under or in front of appliance. | Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil électrique au dessus ou en dessous de l'appareil. |
| ||||||||||
| ||||||||||||
DANGER: Risk of electrical shock. Disconnect power supply before servicing. Replace glass only with 5mm | DANGER: Il y a risque de décharge électrique. Déconnectez le fil électrique de la prise de contact avant le service. | |||||||||||
Remplacez la vitre seulement avec une vitre céramique de 5 mm disponible chez votre fournisseur. | ||||||||||||
ceramic available from your | dealer. To | start, set thermostat above room temperature, the stove will light | ||||||||||
Pour allumer, monter la température du thermostat au dessus de | la température de la pièce, le poêle s'allumera | |||||||||||
automatically. To shutdown, set thermostat to below room temperature. For further instruction refer to owner's | ||||||||||||
automatiquement. Pour éteindre, descendre la température du thermostat en dessous de la température de la pièce. Pour des | ||||||||||||
manual.Keep viewing and ash removal doors tightly closed during operation. | ||||||||||||
instructions supplémentaires, référez vous au manuel du propriétaire. | Gardez la porte d'ouverture et la porte des cendres |
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS / ESPACESLIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES:
fermées hermétiquement durant l'opération.
|
| A |
|
|
|
| C |
|
|
| D |
|
|
|
|
|
|
|
|
| E |
|
|
| C |
|
| A |
|
|
|
|
|
| A | Back Wall to stove / Mur Arrière du poêle |
| 2"/51mm | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| C |
|
| B | Side Wall to Cast Top / Mur De Côté du haut |
| 6"/152mm | |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| CORNER INSTALLATION / NSTALLATION DU COIN : |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| L |
|
| C | Side Wall / Mur De Côté |
| 2"/51mm | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
| B |
|
|
|
|
|
|
| C |
|
|
|
|
|
|
|
| B |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| B |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| E |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| VERTICAL ADAPTER KIT INSTALLATION: |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| P |
|
|
|
|
|
|
| UN ASSEMBLAGE POUR ADAPTEUR POUR INSTALLATION VERTICALE: | |||||||||
Note 1: In residential installations, when using Parts |
|
|
|
|
|
|
| D | Back Wall to Flue Pipe / Mur Arrière tuyau rigide |
| 3"/76mm | |||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
| B | Side Wall to Cast Top / Mur De Côté du haut |
| 6"/152mm | ||||||||||||||||||||||||||||||||||||||||
|
| F |
|
|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||
Note 1: Dans les installations résidentielles, lorsque les pièces |
|
|
|
|
|
|
|
| D |
|
| CORNER INSTALLATION WITH VERTICAL ADAPTER KIT: |
|
|
| |||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
| INSTALLATION DU COIN AVEC UN ASSEMBLAGE D'ADAPTEUR VERTICAL: | |||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||
ventilation 3" - 3") et |
|
|
|
|
|
|
|
|
|
|
|
|
| E | Side Wall / Mur De Côté |
| 2"/51mm | |||||||||||||||||||||||||||||||||
pour mur simple de calibre 24 peut être utilisé. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ALCOVE INSTALLATION / INSTALLATION DE L' ALCÔVE: |
|
|
| |||||||||||||
Note 2: In manufactured home installation, when using Part |
|
|
|
|
|
|
|
|
| A |
|
| Max. Alcove Depth: / La profondeur maximum de l'alcôve |
| 36"/914mm | |||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| M |
|
|
|
|
|
|
|
|
|
|
|
|
| A | Back Wall to stove / Mur Arrière du poêle |
| 2"/51mm | ||||
|
| Outside Air Kit |
|
|
|
|
|
|
|
|
|
|
|
|
| B | Side Wall to Cast Top / Mur De Côté du haut |
| 6"/152mm | |||||||||||||||||||||||||||||||
(Part |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| C | Unit corner to diagonal wall / |
| 2" (51mm) | |||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||||||||||||||||
Note 2: Pour l'installation dans les maisons préfabriquées, lorsque les pièces |
|
|
|
|
|
|
|
|
|
|
|
|
| F | Top of Unit to Combustibles / Du poêle du haut combustibles |
| 12.5"/318mm | |||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||||||||||||
l'adapteur de ventilation 3" - 3") et |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Alcove vertical installation / Installation verticale de l'alcôve | |||||||||||||||||||||||||||||||||||
tuyau connecteur enregistré pour mur double. Un assemblage d'air extérieur (pièce |
|
|
|
|
|
|
|
|
|
|
|
|
| D | Back Wall to Flue Pipe / Mur Arrière tuyau rigide |
| 3"/76mm | |||||||||||||||||||||||||||||||||
au |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| FLOOR PROTECTION / PROTECTION DU SOL |
|
|
| ||||||||||||||||||
|
| H* |
|
|
| *Un protecteur incombustible de plancher doit s'étendre sous le conduit de cheminée pour une | ||||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
| horizontal venting or under | the Top Vent Adapter with vertical installation. |
|
| installation de ventilation horizontale ou sous un adapteur de ventilation de dessus pour une | ||||||||||||||||||||||||||||||||||||||||
| G |
|
| G |
| RECOMMENDED IN USA; REQUIRED IN CANADA |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| installation verticale. | |||||||||||||||||||||||||
|
| I |
| Floor protector must be noncombustible material, extending beneath heater and to the |
|
| Le poêle doit être placé sur une assise non combustible s’étendant tout autour de lui, comme les | |||||||||||||||||||||||||||||||||||||||||||
G = 2"/51mm | front/sides/rear as indicated. Measure front distance (I) from the surface of the glass door. |
|
| schémas l’indiquent. Mesurez la distance du devant (I) de la surface de la porte vitrée. |
| |||||||||||||||||||||||||||||||||||||||||||||
H* = 2"/51mm |
|
|
|
|
|
|
|
|
| U.S. ENVIRONMENTAL PROTECTION AGENCY This model is exempt from EPA certification under 40 CFR 60.531 by definition [Wood Heater (A) | ||||||||||||||||||||||||||||||||||||||||
I = 6"/152mm |
| 1445 Highway North |
| 2008 | 2009 2010 |
|
| JAN | FEB |
| MAR | APR | MAY | JUNE JULY AUG SEPT OCT NOV | DEC |
|
| |||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
| Colville, WA 99114 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
| www.quadrafire.com |
| DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE |
| Made in China/Fait Aux Chine |
|
|
| ||||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Testing Lab & Report Number
Serial Number
Model
Mfg Date
Page 2 | September 1, 2008 |