Hearth and Home Technologies CB1200-B Reference Materials, Component Function & Location

Page 35

R

CB 1200 Pellet Stove

 

 

 

Reference Materials

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿

 

 

 

 

 

 

Component Function & Location

 

When describing the location of a component,

 

 

 

 

 

 

 

 

 

 

it is always AS YOU FACE THE FRONT OF

 

A.11

 

 

 

 

 

 

1. Control Box

 

 

 

 

 

THE APPLIANCE.

 

 

 

a. The control box is located under a small cover in the

 

 

 

 

 

7.

Heat Exchangers

 

 

 

right rear corner of the inside of the hopper.

 

 

 

b. There is a light located inside of the control box. The

The heat exchangers transfer hot air from the exhaust system

 

into convection air. Lift the stove top to access the heat

 

internal light will turn green when the appliance has

 

reached a temperature of 200οF (93°C) in the firepot

exchangers. There are 2 clean out rods located under the

 

and will turn red when it reaches 600oF (315°C).

heat exchangers.

 

 

 

c. There is also an internal blue light located in the upper

8. Heat Output Switch

 

 

 

left corner of the control box. When you plug in the

The heat output switch is located on the upper right side panel.

 

appliance the blue light will automatically start blinking

The function of the heat ouput switch is to regulate the burn

 

1 blink every 10 seconds for the first 60 seconds and

rates; low, medium, and high settings.

 

then will stop.

 

 

 

 

9.

Igniter

 

 

 

 

 

 

 

 

 

 

 

 

NOTE:

 

 

 

 

The igniter is mounted on the base of the firepot. Combustion

 

Do NOT open the control box. This will void the

 

air travels over the red hot igniter creating super heated air

 

warranty. If you need to plug in or remove the control

 

that ignites the pellets.

 

 

 

box you must first unplug the appliance.

 

 

10. Junction Box And Wiring Harness

 

 

 

 

 

 

 

The junction box is located on the right side of the appliance,

 

2. Convection Blower

 

 

 

 

 

behind the interior shield. The junction box and wiring harness

 

The convection blower is mounted at the bottom rear of the

are replaced as one component.

 

appliance. There are 2 impellers, one on each side of the

11.

Power Supply

 

 

 

motor. The convection blower pushes heated air through the

The power outlet is located on the back of the appliance,

 

heat exchange system into the room.

 

 

lower right corner. Check the wall receptacle for 120 volt,

 

3. Combustion (Exhaust) Blower

 

 

 

 

 

60 Hz (standard current). Make sure the outlet is grounded

 

The combustion blower is mounted on the lower left side

and has the correct polarity.

A good surge protector is

 

on rear of appliance.

The blower is designed to pull the

recommended.

 

 

 

exhaust from the appliance and push it out through the

12.

Red Call Light

 

 

 

venting system.

 

 

 

 

The red call light is on the front of the junction box, next to the

 

4. Feed System

 

 

 

 

 

 

 

 

 

reset button. The function of the red call light is to indicate

 

The feed system is located in the hopper under the feed

that the thermostat is calling for heat.

 

motor cover box on the left side of the appliance and can

13.

Reset Button

 

 

 

be removed as an entire assembly. The assembly includes

The reset button is located on the right side of the apppliance

 

the feed motor, mounting bracket, bearing and feed spring

next to the red call light. The function of the button is to

 

(auger). The hollow feed spring (auger) pulls pellets up the

momentarily open the thermostat circuit, which restarts the

 

feed tube from the hopper area and drops them down the

system.

 

 

 

feed chute into the firepot.

 

 

14.

Thermocouple

 

 

 

5. Firepot

 

 

 

 

 

 

 

 

 

 

 

The thermocouple is located on top of the firepot inside

 

The firepot is made of high quality ductile iron and has a

 

the thermocouple cover (ceramic protection tube). The

 

cleaning pull-out rod.

The floor of the firepot opens for

thermocouple sends a millivolt signal to the control box

 

cleaning when you pull out the rod. Be sure that the floor

indicating the preset temperatures of the green and red lights

 

returns to a completely closed position or your appliance will

have been obtained.

 

 

 

not operate properly.

 

 

 

 

15.

Thermostat

 

 

 

6. Fuse

 

 

 

 

 

 

 

 

 

 

 

The appliance is designed to run on a 12 volt AC thermostat.

 

The fuse is located on the front of the junction box on the

 

The heat anticipator should be set on the lowest setting

 

right side of the appliance. The fuse will blow should a short

available.

 

 

 

occur and shut off power to the appliance.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

September 1, 2008

 

 

7014-082D

Page 35

Image 35
Contents Hot glass will cause burns Classic BAY 1200 Pellet StoveBehind left side curtain on outside of hopper wall Testing Lab & Report Number Serial Number Model Mfg DateCB 1200 Pellet Stove Table of Contents Listing and Code Approvals Appliance Location Design, Installation & Location ConsiderationsFire Safety Getting StartedInspect Appliance & Components and Pre-Use Check List CB 1200 Pellet Stove Tools And Supplies NeededAppliance Dimensions 3Dimensions and ClearancesCB 1200 Pellet Stove Clearances to Combustibles UL and ULC Hearth Pad Requirements Exception for Horizontal InstallationsCB 1200 Pellet Stove Hearth Pad Requirements UL and ULC 4Vent Information Example Pipe Selection ChartCB 1200 Pellet Stove Equivalent Feet of Pipe Example of 3 Elbow-Rear Vent Termination CalculatonAlcove 5Venting SystemsCB 1200 Pellet Stove Through The Wall Straight OutDegree Through The Wall & Vertical CB 1200 Pellet Stove VerticalAlternate Masonry Masonry6Mobile Home Outside Air Kit Instructions Rear Installation Floor Installation7Appliance Set-Up See Figure CB 1200 Pellet Stove Top Vent Adapter InstallationRear Vent and Rear Vent to Top Vent Adapter Installation Installing the Top Vent AdapterInstalled Clip Right Installing Logo Nickel OnlyCharred Areas in the Back Top Log, LeftTo adjust latches CB 1200 Pellet Stove Door InstallationThermostat Installation To install doorFuel Size And Material General Operating Information 8Operating InstructionsStarting Your First Fire Feed Rate Adjustment InstructionsCB 1200 Pellet Stove Ignition Cycles Frequently Asked QuestionsButton. See .1, page 22 . When you press Possible Cause Corrective Action TroubleshootingSymptom Page Page Frequency Daily Weekly Monthly Yearly Quick Reference Maintenance ChartCleaning or Inspection 10Maintaining & Servicing Your ApplianceAsh Removal from Firebox Cleaning Firepot with Cleaning Rod & Firepot ScraperCleaning Ash Pan Cleaning Heat Exchanger Chambers & Drop TubeCleaning Exhaust Blower Requires No Lubrication Cleaning Beneath Heat Exchanger Door Latch InspectionCleaning Exhaust Path Cleaning the Hopper Cleaning the GlassPreparing Firebox for Non-Burn Season Frequency Yearly Cleaning the Top Vent AdapterConvection Blower Replacement CB 1200 Pellet Stove High Ash Fuel Content MaintenanceRe-install blower to blower housing Exhaust Blower Replacement Remove existing blowerInstall new blower Replacing Side Glass Screws Glass ReplacementComponent Function & Location Reference MaterialsSnap Disc #2 Thermostat Override 200F Vacuum SwitchWiring Harness See .1 below Snap Disc #1 Convection Blower 145FCB 1200 Pellet Stove Component Locations Glass Size Sides 8 wide x 11 high CB 1200 Pellet Stove Exploded ViewsGlass Size Center 13-7/8 wide x 11 high Nbr Description CB 1200 Pellet Stove Item # Parts Alphabetical Order CB 1200 Pellet Stove Service Parts and AccessoriesItem # Service Parts Alphabetical Order Appliance AccessoriesDate of Service Performed By Description of Service CB 1200 Pellet Stove Service And Maintenance LogCB 1200 Pellet Stove Homeowner’s Notes CONDITIONS, Exclusions & Limitation of Liability CB 1200 Pellet Stove Warranty PolicyHearth & Home Technologies Limited Warranty Cont’d Contact Information