Hearth and Home Technologies CB1200-B owner manual

Page 27

R

CB 1200 Pellet Stove

Symptoms

Possible Cause

Corrective Action

Convection blower fails to

#1 snap disc defective.

Replace snap disc.

start.

Blower not plugged in.

Check that blower is plugged into wire har-

 

 

 

ness.

 

Blower is defective.

Replace blower.

 

Control box is defective.

Replace control box.

Exhaust blower fails to

Blower not plugged in.

Check that blower is plugged into wire har-

start or does not shut off.

 

ness.

 

Blower is clogged with ash.

Clean exhaust system.

 

Blower is defective.

Replace blower.

 

Control box is defective.

Replace control box.

Large, lazy flame, orange

Dirty appliance.

Clean unit, including firepot, heat exchang-

color. Black ash on glass.

Poor fuel quality, high ash content.

ers and venting system. Remove stainless

 

 

steel baffle from firebox to clean ash from

 

 

on top of baffle. Clean behind rear brick

 

 

panels. Change fuel brand to premium.

 

Firepot clean-out plate not completely

Check that firepot clean-out plate is fully

 

closed.

closed.

 

 

Reduce feed rate using feed rate adjustment

 

Excessive amount of fuel.

control rod located inside hopper.

Nuisance shutdowns.

Low flame.

Increase feed by opening feed rate adjust-

 

 

ment control rod located inside hopper.

 

Sawdust buildup in hopper.

Clean hopper, see page 30.

 

Feed motor is reversing.

Check for good connections between feed

 

 

motor and wire harness.

 

Defective thermocouple.

Replace thermocouple.

 

Defective control box.

Replace control box.

 

Firepot more than 1/2 full.

See page 31 for detailed instructions for

 

 

“High Ash Fuel Content Management”

Appliance calls for heat.

Thermocouple is defective or not properly

Check connections on thermocouple or

Call light illuminates.

plugged in.

replace if defective.

Exhaust blower starts.

 

A flashing yellow light on the control box

No feed or igniter.

 

indicates a problem with the thermocouple.

 

Defective control box

Replace control box.

September 1, 2008

7014-082D

Page 27

Image 27
Contents Hot glass will cause burns Classic BAY 1200 Pellet StoveTesting Lab & Report Number Serial Number Model Mfg Date CB 1200 Pellet StoveBehind left side curtain on outside of hopper wall Table of Contents Listing and Code Approvals Appliance Location Design, Installation & Location ConsiderationsFire Safety Getting StartedInspect Appliance & Components and Pre-Use Check List CB 1200 Pellet Stove Tools And Supplies NeededAppliance Dimensions 3Dimensions and ClearancesCB 1200 Pellet Stove Clearances to Combustibles UL and ULC Exception for Horizontal Installations CB 1200 Pellet Stove Hearth Pad Requirements UL and ULCHearth Pad Requirements 4Vent Information Example Pipe Selection ChartCB 1200 Pellet Stove Equivalent Feet of Pipe Example of 3 Elbow-Rear Vent Termination CalculatonAlcove 5Venting SystemsStraight Out DegreeCB 1200 Pellet Stove Through The Wall Through The Wall & Vertical CB 1200 Pellet Stove VerticalAlternate Masonry Masonry6Mobile Home Rear Installation Floor Installation 7Appliance Set-UpOutside Air Kit Instructions See Figure CB 1200 Pellet Stove Top Vent Adapter InstallationRear Vent and Rear Vent to Top Vent Adapter Installation Installing the Top Vent AdapterInstalled Clip Right Installing Logo Nickel OnlyCharred Areas in the Back Top Log, LeftTo adjust latches CB 1200 Pellet Stove Door InstallationThermostat Installation To install doorFuel Size And Material General Operating Information 8Operating InstructionsStarting Your First Fire Feed Rate Adjustment InstructionsFrequently Asked Questions Button. See .1, page 22 . When you pressCB 1200 Pellet Stove Ignition Cycles Troubleshooting SymptomPossible Cause Corrective Action Page Page Frequency Daily Weekly Monthly Yearly Quick Reference Maintenance ChartCleaning or Inspection 10Maintaining & Servicing Your ApplianceAsh Removal from Firebox Cleaning Firepot with Cleaning Rod & Firepot ScraperCleaning Ash Pan Cleaning Heat Exchanger Chambers & Drop TubeCleaning Exhaust Blower Requires No Lubrication Cleaning Beneath Heat Exchanger Door Latch InspectionCleaning Exhaust Path Cleaning the Hopper Cleaning the GlassPreparing Firebox for Non-Burn Season Frequency Yearly Cleaning the Top Vent AdapterConvection Blower Replacement CB 1200 Pellet Stove High Ash Fuel Content MaintenanceExhaust Blower Replacement Remove existing blower Install new blowerRe-install blower to blower housing Replacing Side Glass Screws Glass ReplacementComponent Function & Location Reference MaterialsSnap Disc #2 Thermostat Override 200F Vacuum SwitchWiring Harness See .1 below Snap Disc #1 Convection Blower 145FCB 1200 Pellet Stove Component Locations CB 1200 Pellet Stove Exploded Views Glass Size Center 13-7/8 wide x 11 highGlass Size Sides 8 wide x 11 high Nbr Description CB 1200 Pellet Stove Item # Parts Alphabetical Order CB 1200 Pellet Stove Service Parts and AccessoriesItem # Service Parts Alphabetical Order Appliance AccessoriesDate of Service Performed By Description of Service CB 1200 Pellet Stove Service And Maintenance LogCB 1200 Pellet Stove Homeowner’s Notes CONDITIONS, Exclusions & Limitation of Liability CB 1200 Pellet Stove Warranty PolicyHearth & Home Technologies Limited Warranty Cont’d Contact Information