Contents
SVC MANUALExploded View
Table of Contents
Be sure not to do Be sure to follow the instruction
Safety Precautions
Installation
Do not modify or extend the power cord
Operation
There is risk of explosion or fire
Oxygen deficiency could occur
Low refrigerant levels may cause product failure
Keep level even when installing the product
On the product. outdoor unit
Occupants
Salt spray directly
Solvents, etc
Replace all the batteries in the remote
Disuse
Do not drink the water drained from the unit
Model Btu Series
Dimensions
Symbols Used in this Manual
Indoor Unit
Model Btu Series Dimension Mminch 109042.9 30011.8 1787.0
9k, 12k
Outdoor Unit
18k, 24k
Introduction
Features
Read carefully, and then follow step by step
Installation
Installation Parts
Installation Tools
Additional drain pipe
Installation Map
Operation Indication Lamps
This Product Contains R-410A Refrigerant
Confirm The Refrigerant
Outdoor unit
Rooftop Installations
Select The Best Location
Indoor unit
Evap Moz/ft
Piping Length And Elevation
Drill a Hole In The Wall
How To Mount Installation Plate
Putting nut on
Flaring Work
Cut the pipes and the cable
Burrs removal
Indoor
Connecting The Piping
Indoor unit installation
Tighten the flare nut with a wrench
Wrap the insulation material around the connecting portion
Connecting cable
Insert the connecting cable into the indoor unit
Indoor unit installation
Connection Indoor
Incorrect case
Correct case
Connection Of Piping -Outdoor
Connection Of The Drain Hose
Capacity
Connection Of The Cable
Installation
Avoid these situations
Checking The Drainage
Drain piping
Drain hose should point downward for easy drain flow
Forming The Piping
Preparation
Dry nitrogen gas cylinder to this service port
Air Purging
Air purging With Vacuum Pump
Finishing the job
Evacuation
Btu/h
Charging
Evaluation of the performance
Prepare remote control
Test Running
Settlement of outdoor unit
Function of Controls
Cooling Mode Operation
Healthy Dehumidification Mode
Operation
Defrost Control
Heating Mode Operation
Jet Cool Mode Operation H/P Model
Sleep Timer Operation
Chaos Natural Wind Mode
Jet Cool Mode Operation C/O Model
Protection of the evaporator pipe from frosting
Forced operation
Test operation
Auto restart
Thermistor open/short
Display Function
Self-diagnosis Function
Heating Model
Remote Control Operations
To remove the Grille from the Chassis
Disassembly
To remove the Evaporator
When repair, do not damage the Caution label
To remove the Motor Cover
Cooling & Heating Models
Troubleshooting Guide
Refrigeration Cycle Diagram
Cooling Only Models
Way Valve Liquid Side
Way, 3-way Valve
Pumping Down
Procedure
Balance Refrigerant of the 3-way Valve
Vacuum pump
After Evacuation
Gas Charging
Additional gas charging
Method of using graph
Method of using equation
According to Indoor & Outdoor Temperature
Trouble analysis
Cycle Parts
Product does not operate at all
Electronic Parts 9k model
Electronic Parts 18k model
Product is not operate with the remote controller
Compressor/Outdoor Fan are unable to drive.9k Model
Compressor/Outdoor Fan are unable to drive.18k Model
Nector
When indoor Fan does not operate
When Vertical Louver does not operate
When a comunication error occurs
Indoor Unit
Phenomena in case of connecting error
Outdoor Unit
Electric Control Device
Schematic Diagram
Outdoor 9k, 12k
Outdoor 18k, 24k
Models 9k, 12k, 18k, 24k
Wiring Diagram
Models 9kC/O Models 12kH/P, 12kC/O, H/P
Models 18kC/O Models 18kH/P, 24kC/O, H/P
Components Location
Main P.W.B Assembly TOP View Bottom View
TOP View Bottom View
Outdoor9k, 12k
Outdoor18k, 24k
6871A20680
6871A20681
Cooling Only
Product Specifications
LS090HP LS120HP LS180HP LS240HP
Cooling & Heating
Exploded View
Outdoor Unit 9k, 12k C/O Seriess
Outdoor Unit 9k, 12k H/P Seriess
Outdoor Unit 18kC/O Seriess
W0CZZB
Outdoor Unit 24kC/O Seriess
Outdoor Unit 18k, 24k H/P Seriess
No MFL32351801 December