7.0 Site Requirements

7.3 Ventilation of Compartments

1. Where the appliance is installed in a cupboard or compartment, no air vents are required.

2. BS 5440: Part 2 Clause 4.2 refers to room sealed appliances installed in compartments. The appliance will run sufficiently cool without ventilation.

7.4 Gas Supply

1. The gas installation should be in accordance with the relevant standards. In GB this is BS 6891. In IE this is the current edition of I.S. 813 “Domestic Gas Installations”.

2. The connection to the appliance is a 22mm copper tail located at the rear of the gas service cock (Fig. 10).

3. Ensure that the pipework from the meter to the appliance is of adequate size. Do not use pipes of a smaller diameter than the boiler gas connection (22mm).

7.5 Electrical Supply

1. External wiring must be correctly earthed, polarised and in accordance with relevant regulations/rules. In GB this is the current I.E.e. Wiring Regulations. In IE reference should be made to the current edition of ETCI rules.

2. The mains supply is 230V ~ 50Hz fused at 3A.

NOTE: The method of connection to the electricity supply must facilitate complete electrical isolation of the appliance.

Connection may be via a fused double-pole isolator with a contact separation of at least 3mm in all poles and servicing the boiler and system controls only.

Fig. 10

Gas Service Cock

© Baxi Heating UK Ltd 2007

15

Image 15
Contents Installation & Service Instructions Contents Scheme Members only Installer Notification GuidelinesImportant Installation, Commissioning, Service & Repair LegislationCodes of Practice, most recent version should be used Technique Safe Manual HandlingGeneral PreparationCase Front Panel Control Box Data Badge IntroductionDescription Optional ExtrasGeneral Layout Layout1211 30 31 32 Appliance Operation Central Heating Mode FigDomestic Hot Water Mode Fig Frost Protection ModePerforma 30 HE Technical DataDimensions and Fixings Bypass System DetailsInformation Central Heating CircuitPressure Relief Valve Fig System Filling and PressurisingDomestic Hot Water Circuit Fig ShowersHard Water Areas Site Requirements LocationClearances Figs Ventilation of Compartments Gas SupplyElectrical Supply Condensate Drain External termination via internalOr Door Plume Displacement KitFlue Built-in element such as a window frame. See BS 5440 PtThis bend is equivalent to 1 metre Flue OptionsHorizontal Flues Horizontal Flue Systems1m extension 45bend 25m 91.5bend Vertical Flues Twin PipeTwin & Vertical Flue Systems Metre for each 91.5 elbow Metre for each 45 elbowFlue Accessories Key Accessory Size5111079 Flue Duct Adaptor Air duct adaptorFor Twin Flue Systems fit the adaptors as follows Terminal Guard Fig Flue DimensionsFor Roof Terminals Flue TrimRing Bracket Metres 60Ø Exhaust Flue Pipe 60Ø Support Plume DisplacementPlume Displacement Kit b Elbow/Plume Outlet AssemblyDetermining Permissible Lengths Screw 30mmGeneral Fitting Notes Min metres Flue Trim SpigotPlume Outlet Elbow Preparing The Boiler InstallationInitial Preparation FlushingRemove the sealing caps from the boiler connections Fitting The BoilerCondensate Drain see section Pressure Relief Valve Discharge Pipe Wall PlateWall Thickness Flue Elbow Adaptor Fitting The FlueVertical Flue WasteY Flue Inner Flue Support Bracket Flue ElbowPreliminary Electrical Checks Making The Electrical ConnectionsCommissioning the Boiler Commissioning the BoilerPressure Test Point Sealing Screw Checking the Burner PressureCompletion CompletionCase Front Panel Facia Panel 13 .1 Annual Servicing Servicing the BoilerAnnual Servicing Pressure Switch Fig Changing ComponentsFan Figs 14.0 Changing Components Heat Exchanger FigBurner Fig Reassemble in reverse order Injectors FigElectrodes Fig Insulation FigGas Valve Fig Central Heating Temperature Sensor FigSafety Thermostat Fig DHW Temperature Sensor FigPump Head Only Fig Pump Complete FigAutomatic Air Vent Fig Pressure Gauge Figs Expansion Vessel FigCondensate Trap Fig 14.19 P.C.B. Fig Selector Switch FigPlate Heat Exchanger Fig Flow Regulator Figs Diverter Valve AssemblyFlue Overheat Thermostat Fig Secondary Heat Exchanger FigControl PCB Illustrated Wiring DiagramFault Finding Turn selector to neon illuminated Microswitch terminalsDiverter valve spindle Assembly faulty Domestic Hot Water Follow operational sequenceAcross terminals 5 Replace microswitch Check wiring PCB A4 connector Replace selector Terminals 4Replace pump PCB A4 connector terminals 3 Replace PCB PCB A2 connector, isGas at burner PCB A1 connector has 230V ACTurn selector switch To ‘Reset’ positionON/OFF/RESET selector when turned to ‘Reset’ position 154 Short Parts ListShort Parts List 131GAS Boiler Commissioning Checklist Service Interval Record Potterton
Related manuals
Manual 12 pages 48.65 Kb

30 HE specifications

The Baxi Potterton 30 HE is a popular choice among homeowners seeking an efficient and reliable boiler solution. Recognized for its compact design and advanced technologies, this boiler is ideal for various residential heating needs.

One of the standout features of the Baxi Potterton 30 HE is its high efficiency rating, which ensures lower energy consumption and reduced utility bills. With an impressive efficiency of up to 90%, this boiler operates at a much higher capacity compared to older models, making it both environmentally friendly and cost-effective. The 30 HE is particularly well-suited for medium to larger homes with a higher demand for hot water.

The Baxi Potterton 30 HE incorporates a range of innovative technologies aimed at enhancing performance and reliability. The automatic modulation function adjusts the boiler's output according to demand, ensuring that it only works as hard as necessary. This not only prolongs the lifespan of the unit but also maximizes comfort levels in the home.

Another feature of the 30 HE is its low noise operation. This boiler has been specifically designed to minimize sound, allowing it to operate quietly in the background without disturbing daily activities. This makes it an ideal choice for homes where noise can be a concern, particularly in open-plan living spaces.

The compact dimensions of the Baxi Potterton 30 HE make it easy to install in various locations, whether it be in a kitchen, utility room, or even a loft space. Its lightweight construction further simplifies the installation process, saving both time and labor costs.

In terms of user-friendliness, the boiler is equipped with an intuitive control panel that allows homeowners to easily adjust settings and monitor performance. This user-centric design ensures that even those who may not be technically inclined can manage their heating requirements with ease.

Safety features are also a priority in the design of the Baxi Potterton 30 HE. It includes built-in safety mechanisms such as frost protection and a burner pressure monitoring system, which work to prevent overheating and ensure optimal operation.

Overall, the Baxi Potterton 30 HE is an efficient, reliable, and user-friendly boiler that meets the heating demands of modern homes. Its blend of advanced technologies, compact size, and focus on safety make it a standout choice for homeowners seeking a high-performance heating solution.