Baxi Potterton 30 HE manual Introduction, Description, Optional Extras

Page 6

Case Front Panel

Control Box

Fig. 1

Data Badge

1.0Introduction

1.1Description

1.The Potterton Performa 30 HE is a fully automatic gas fired wall mounted condensing combination boiler. It is room sealed and fan assisted, and will serve central heating and mains fed domestic hot water.

2.The boiler is set to give a maximum output of

31.0kW (condensing).

3.It is designed for use on Natural Gas (G20) and can be converted to use Propane.

4.The boiler is suitable for use only on fully pumped sealed heating systems. Priority is given to domestic hot water.

5.The boiler data badge gives details of the model, serial number and Gas Council number and is situated on the control box. It is visible when the case front panel is removed (Fig. 1).

6.The boiler is intended to be installed in residential / commercial / light industrial E.M.C. environments on a governed meter supply only.

7.The boiler must be installed with one of the purpose designed flues such as the standard horizontal flue kit, part no. 5111073.

8.All systems must be thoroughly flushed and treated with inhibitor (see section 6.2).

1.2Optional Extras

Various flue extensions, bends, vertical flue kits, control accessories etc. are available as optional extras. These are detailed in a separate publication.

6© Baxi Heating UK Ltd 2007

Image 6
Contents Installation & Service Instructions Contents Installer Notification Guidelines Scheme Members onlyImportant Installation, Commissioning, Service & Repair LegislationCodes of Practice, most recent version should be used Preparation Safe Manual HandlingGeneral TechniqueOptional Extras IntroductionDescription Case Front Panel Control Box Data BadgeGeneral Layout Layout1211 30 31 32 Frost Protection Mode Central Heating Mode FigDomestic Hot Water Mode Fig Appliance OperationTechnical Data Performa 30 HEDimensions and Fixings Central Heating Circuit System DetailsInformation BypassSystem Filling and Pressurising Pressure Relief Valve FigDomestic Hot Water Circuit Fig ShowersHard Water Areas Site Requirements LocationClearances Figs Ventilation of Compartments Gas SupplyElectrical Supply External termination via internal Condensate DrainBuilt-in element such as a window frame. See BS 5440 Pt Plume Displacement KitFlue Or DoorHorizontal Flue Systems Flue OptionsHorizontal Flues This bend is equivalent to 1 metreMetre for each 91.5 elbow Metre for each 45 elbow Vertical Flues Twin PipeTwin & Vertical Flue Systems 1m extension 45bend 25m 91.5bendFlue Accessories Key Accessory Size5111079 Flue Duct Adaptor Air duct adaptorFor Twin Flue Systems fit the adaptors as follows Flue Trim Flue DimensionsFor Roof Terminals Terminal Guard FigElbow/Plume Outlet Assembly Plume DisplacementPlume Displacement Kit b Ring Bracket Metres 60Ø Exhaust Flue Pipe 60Ø SupportDetermining Permissible Lengths Min metres Flue Trim Spigot 30mmGeneral Fitting Notes ScrewPlume Outlet Elbow Flushing InstallationInitial Preparation Preparing The BoilerPressure Relief Valve Discharge Pipe Wall Plate Fitting The BoilerCondensate Drain see section Remove the sealing caps from the boiler connectionsFitting The Flue Wall Thickness Flue Elbow AdaptorWasteY Flue Inner Flue Support Bracket Flue Elbow Vertical FlueMaking The Electrical Connections Preliminary Electrical ChecksCommissioning the Boiler Commissioning the BoilerChecking the Burner Pressure Pressure Test Point Sealing ScrewCompletion CompletionCase Front Panel Facia Panel Servicing the Boiler 13 .1 Annual ServicingAnnual Servicing Pressure Switch Fig Changing ComponentsFan Figs 14.0 Changing Components Heat Exchanger FigBurner Fig Insulation Fig Injectors FigElectrodes Fig Reassemble in reverse orderDHW Temperature Sensor Fig Central Heating Temperature Sensor FigSafety Thermostat Fig Gas Valve FigPump Head Only Fig Pump Complete FigAutomatic Air Vent Fig Pressure Gauge Figs Expansion Vessel FigCondensate Trap Fig Selector Switch Fig 14.19 P.C.B. FigPlate Heat Exchanger Fig Diverter Valve Assembly Flow Regulator FigsSecondary Heat Exchanger Fig Flue Overheat Thermostat FigIllustrated Wiring Diagram Control PCBFault Finding Domestic Hot Water Follow operational sequence Microswitch terminalsDiverter valve spindle Assembly faulty Turn selector to neon illuminatedPCB A2 connector, is Check wiring PCB A4 connector Replace selector Terminals 4Replace pump PCB A4 connector terminals 3 Replace PCB Across terminals 5 Replace microswitchTo ‘Reset’ position PCB A1 connector has 230V ACTurn selector switch Gas at burnerON/OFF/RESET selector when turned to ‘Reset’ position 131 Short Parts ListShort Parts List 154GAS Boiler Commissioning Checklist Service Interval Record Potterton
Related manuals
Manual 12 pages 48.65 Kb

30 HE specifications

The Baxi Potterton 30 HE is a popular choice among homeowners seeking an efficient and reliable boiler solution. Recognized for its compact design and advanced technologies, this boiler is ideal for various residential heating needs.

One of the standout features of the Baxi Potterton 30 HE is its high efficiency rating, which ensures lower energy consumption and reduced utility bills. With an impressive efficiency of up to 90%, this boiler operates at a much higher capacity compared to older models, making it both environmentally friendly and cost-effective. The 30 HE is particularly well-suited for medium to larger homes with a higher demand for hot water.

The Baxi Potterton 30 HE incorporates a range of innovative technologies aimed at enhancing performance and reliability. The automatic modulation function adjusts the boiler's output according to demand, ensuring that it only works as hard as necessary. This not only prolongs the lifespan of the unit but also maximizes comfort levels in the home.

Another feature of the 30 HE is its low noise operation. This boiler has been specifically designed to minimize sound, allowing it to operate quietly in the background without disturbing daily activities. This makes it an ideal choice for homes where noise can be a concern, particularly in open-plan living spaces.

The compact dimensions of the Baxi Potterton 30 HE make it easy to install in various locations, whether it be in a kitchen, utility room, or even a loft space. Its lightweight construction further simplifies the installation process, saving both time and labor costs.

In terms of user-friendliness, the boiler is equipped with an intuitive control panel that allows homeowners to easily adjust settings and monitor performance. This user-centric design ensures that even those who may not be technically inclined can manage their heating requirements with ease.

Safety features are also a priority in the design of the Baxi Potterton 30 HE. It includes built-in safety mechanisms such as frost protection and a burner pressure monitoring system, which work to prevent overheating and ensure optimal operation.

Overall, the Baxi Potterton 30 HE is an efficient, reliable, and user-friendly boiler that meets the heating demands of modern homes. Its blend of advanced technologies, compact size, and focus on safety make it a standout choice for homeowners seeking a high-performance heating solution.