Baxi Potterton 30 HE manual Fitting The Flue, Wall Thickness Flue Elbow Adaptor

Page 29

Fig. 34

Wall Thickness

Flue Elbow

(X)

Adaptor

Fig. 35

(X)

Wall Thickness

Fig. 36

10.0Installation

10.7Fitting The Flue

HORIZONTAL FLUE

1.The standard flue is suitable for lengths between 100mm minimum and 685mm maximum, as measured from the edge of the flue elbow outlet to the joint between the terminal and air duct (Fig. 34).

2.Locate the flue elbow on the adaptor at the top of the boiler. Set the elbow to the required orientation (Fig. 35).

NOTE: The flue elbow is angled at 91.5 degrees to ensure a fall back to the boiler.

3.Measure the distance from the outside wall face to the elbow. This dimension will be known as ‘X’ (Fig. 36).

4.To dimension ‘X’ add 50mm. This dimension to be known as ‘Y’.

IMPORTANT: Check all dimensions before cutting.

© Baxi Heating UK Ltd 2007

29

Image 29
Contents Installation & Service Instructions Contents Scheme Members only Installer Notification GuidelinesCodes of Practice, most recent version should be used Important Installation, Commissioning, Service & RepairLegislation General Safe Manual HandlingPreparation TechniqueDescription IntroductionOptional Extras Case Front Panel Control Box Data Badge1211 30 31 32 General LayoutLayout Domestic Hot Water Mode Fig Central Heating Mode FigFrost Protection Mode Appliance OperationPerforma 30 HE Technical DataDimensions and Fixings Information System DetailsCentral Heating Circuit BypassPressure Relief Valve Fig System Filling and PressurisingHard Water Areas Domestic Hot Water Circuit FigShowers Clearances Figs Site RequirementsLocation Electrical Supply Ventilation of CompartmentsGas Supply Condensate Drain External termination via internalFlue Plume Displacement KitBuilt-in element such as a window frame. See BS 5440 Pt Or DoorHorizontal Flues Flue OptionsHorizontal Flue Systems This bend is equivalent to 1 metreTwin & Vertical Flue Systems Vertical Flues Twin PipeMetre for each 91.5 elbow Metre for each 45 elbow 1m extension 45bend 25m 91.5bend5111079 Flue AccessoriesKey Accessory Size For Twin Flue Systems fit the adaptors as follows Flue Duct AdaptorAir duct adaptor For Roof Terminals Flue DimensionsFlue Trim Terminal Guard FigPlume Displacement Kit b Plume DisplacementElbow/Plume Outlet Assembly Ring Bracket Metres 60Ø Exhaust Flue Pipe 60Ø SupportDetermining Permissible Lengths General Fitting Notes 30mmMin metres Flue Trim Spigot ScrewPlume Outlet Elbow Initial Preparation InstallationFlushing Preparing The BoilerCondensate Drain see section Fitting The BoilerPressure Relief Valve Discharge Pipe Wall Plate Remove the sealing caps from the boiler connectionsWall Thickness Flue Elbow Adaptor Fitting The FlueVertical Flue WasteY Flue Inner Flue Support Bracket Flue ElbowPreliminary Electrical Checks Making The Electrical ConnectionsCommissioning the Boiler Commissioning the BoilerPressure Test Point Sealing Screw Checking the Burner PressureCase Front Panel Facia Panel CompletionCompletion 13 .1 Annual Servicing Servicing the BoilerAnnual Servicing Fan Figs Pressure Switch FigChanging Components Burner Fig 14.0 Changing ComponentsHeat Exchanger Fig Electrodes Fig Injectors FigInsulation Fig Reassemble in reverse orderSafety Thermostat Fig Central Heating Temperature Sensor FigDHW Temperature Sensor Fig Gas Valve FigAutomatic Air Vent Fig Pump Head Only FigPump Complete Fig Condensate Trap Fig Pressure Gauge FigsExpansion Vessel Fig 14.19 P.C.B. Fig Selector Switch FigPlate Heat Exchanger Fig Flow Regulator Figs Diverter Valve AssemblyFlue Overheat Thermostat Fig Secondary Heat Exchanger FigControl PCB Illustrated Wiring DiagramFault Finding Diverter valve spindle Assembly faulty Microswitch terminalsDomestic Hot Water Follow operational sequence Turn selector to neon illuminatedReplace pump PCB A4 connector terminals 3 Replace PCB Check wiring PCB A4 connector Replace selector Terminals 4PCB A2 connector, is Across terminals 5 Replace microswitchTurn selector switch PCB A1 connector has 230V ACTo ‘Reset’ position Gas at burnerON/OFF/RESET selector when turned to ‘Reset’ position Short Parts List Short Parts List131 154GAS Boiler Commissioning Checklist Service Interval Record Potterton
Related manuals
Manual 12 pages 48.65 Kb

30 HE specifications

The Baxi Potterton 30 HE is a popular choice among homeowners seeking an efficient and reliable boiler solution. Recognized for its compact design and advanced technologies, this boiler is ideal for various residential heating needs.

One of the standout features of the Baxi Potterton 30 HE is its high efficiency rating, which ensures lower energy consumption and reduced utility bills. With an impressive efficiency of up to 90%, this boiler operates at a much higher capacity compared to older models, making it both environmentally friendly and cost-effective. The 30 HE is particularly well-suited for medium to larger homes with a higher demand for hot water.

The Baxi Potterton 30 HE incorporates a range of innovative technologies aimed at enhancing performance and reliability. The automatic modulation function adjusts the boiler's output according to demand, ensuring that it only works as hard as necessary. This not only prolongs the lifespan of the unit but also maximizes comfort levels in the home.

Another feature of the 30 HE is its low noise operation. This boiler has been specifically designed to minimize sound, allowing it to operate quietly in the background without disturbing daily activities. This makes it an ideal choice for homes where noise can be a concern, particularly in open-plan living spaces.

The compact dimensions of the Baxi Potterton 30 HE make it easy to install in various locations, whether it be in a kitchen, utility room, or even a loft space. Its lightweight construction further simplifies the installation process, saving both time and labor costs.

In terms of user-friendliness, the boiler is equipped with an intuitive control panel that allows homeowners to easily adjust settings and monitor performance. This user-centric design ensures that even those who may not be technically inclined can manage their heating requirements with ease.

Safety features are also a priority in the design of the Baxi Potterton 30 HE. It includes built-in safety mechanisms such as frost protection and a burner pressure monitoring system, which work to prevent overheating and ensure optimal operation.

Overall, the Baxi Potterton 30 HE is an efficient, reliable, and user-friendly boiler that meets the heating demands of modern homes. Its blend of advanced technologies, compact size, and focus on safety make it a standout choice for homeowners seeking a high-performance heating solution.