State Industries SBN85390NE/A warranty Service, Ignition Module System, System Diagnostics

Page 29

Note: If your container does not have the vent cap and vent boss, drill a 3/16" hole in the handle. When you have finished deliming you will be able to plug this drilled vent with the stainless steel screw that is supplied with the kit.

2.Remove the container's cap and cut the plastic membrane located in the 3/4" IPT opening in the cap. Take care to not damage the threads.

3.Find the 3/4" male adapter, apply teflon tape to the threaded end and screw it into the 3/4" IPT opening in the cap.

4.Put cap with male adapter back on the container and slide 3/4" hose over end of male adapter and fasten in place using hose clamp provided.

Delime using Flo-Jug Method

5.Slide the hose clamp over end of hose and slide hose over the male adapter in the water heater drain opening and secure in place using hose clamp.

6.Lift container to the "Pour" Position, see Figure 16, being careful to keep the vent in the handle above the liquid level and pour the UN•LIME into the heater.

7.Lower container, you may have to place the container on its empty carton to prevent the UN•LIME from flowing back into the container.

8.Let UN•LIME remain in the heater for 5 minutes and then lower the container to the "Drain" Position, see Figure 16.

9.Deliming activity is indicated by foaming on the surface of the UN•LIME. If there is deliming activity, repeat steps 6 thru 8.

Normally, lime removal will be completed within one hour. Severe build-up of lime may take longer than an hour to complete descaling.

Note: To check UN•LIME for continued use, place some scale or white chalk in a glass with a small amount of UN•LIME. If the material is vigorously dissolved by the UN•LIME, it can be reused; if not, the UN•LIME should be replaced.

FIGURE 16

IGNITION MODULE SYSTEM

Before calling your service agent, the following checklist should be examined to eliminate obvious problems from those requiring replacement or servicing.

Check that “main manual gas shutoff valve” is fully open and that gas service has not been interrupted.

Check that after following the appliance OPERATING INSTRUCTIONS, the “Top Knob” of the appliance gas valve is in “ON” position.

Check electrical supply to the appliance for possible blown (or tripped) fusing or power interruption.

Is the water temperature in tank below the thermostat dial setting on the appliance thermostat (calling for heat)?

It is possible that the high limit (E.C.O.) has functioned to shut off the appliance. See FEATURES — Water Temperature Control for reset procedure. Contact your serviceman if limit continues to function to shut off appliance.

SYSTEM DIAGNOSTICS

Your water heater is equipped with an ignition module that incorporates a diagnostic system to assist in troubleshooting the appliance. The indicator codes on the ignition module are as follows:

1 flash

System lockout (retries or cycles exceeded)

2 flashes

Pressure switch stuck close

3 flashes

Pressure switch stuck open

 

4 flashes

Open on high temperature limit switch (eco)

6 flashes

115 volt AC power reversed (check polarity)

7 flashes

Low flame sense signal (make sure flame

 

sensor is in burner flame)

8 flashes

Check ignitor

Table 10.

 

 

continuous flash -> continuous flame sensed > 5 seconds without gas valve

continuous on -> internal control failure - replace ignition control module.

Use this diagnostic system in conjunction with the “OPERATIONAL CHECKLIST” and the “SEQUENCE OF OPERATION” to troubleshoot the appliance.

SERVICE

The installer may be able to observe and correct certain problems which may arise when the unit is put into operation. HOWEVER, it is recommended that only qualified servicemen, using appropriate test equipment, be allowed to service the heater.

As preliminary step, check wiring against diagram, check for grounded, broken or loose wires. Check all wire ends to be sure that they are making good contact.

ELECTRICAL SERVICING

CAUTION

LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION.

VERIFY PROPER OPERATION AFTER SERVICING.

29

Image 29
Contents Models SBN71120NE Thru SBN85390NE/A Series Gasand Electrical Characteristics ROUGH-IN-DIMENSIONSFront View TOP View Back View ROUGH-IN-DIMENSIONS Foreword Table of ContentsGeneral Safety Information High Altitude Installations FeaturesSELF-CLEANING Hydro Cannon High Limit SwitchCirculating Pump Exhaust Inducer Blower AssyDishwashing Machine Requirement UncratingClearances LevelingModel Right Back Ceiling SideAIR Requirements Hard WaterVenting UnconfinedspaceType B GAS Vent Technical Data VentingTechnical Data Venting Water Line Connections Multiple Heater ManifoldWater Potable Heating and Space Relief ValveTube Inlet Installation Installation DIAGRAMS-TOP INLET/OUTLET UsageGeneral Code RestrictionsHorizontal Storage Tank and Forced Circulation Vertical Storage Tank and Forced CirculationPage Circulating Return Line Connection Installation DIAGRAMS-SIDE INLET/OUTLET UsageHeater with Mixing Valve and Recirculated Sanitizing Loop TWO PRE-HEATERS with Booster Heater Horizontal Storage Tank Manifold Kits Model Dimension aTWO Unit Manifold KIT Three Unit Manifold KIT Four Unit Manifold KITSingle Unit Wiring Diagram SBN-120 Through 400A Heater WiringGAS Piping GAS Pipingand Dirt LEG InstallationGAS Pressure Regulator PurgingFilling OperationManifold GAS Pressure in Inches Water Column ALL Models Sequence of Operation Operating Instructions For Your Safety Read Before OperatingLighting and Operation Instructions Water Temperature Control Preventive MaintenanceCheck the Ignitor Assembly Ignitor AssemblyChecking the Input Main BurnerGAS Valves Venting System Remote Storage Tank Temperature ControlHOT Water Odor Anode ROD InspectionDeliming Solvents Tank Cleanout ProcedureDeliming Using FLO-JUG Method System Diagnostics ServiceIgnition Module System Electrical ServicingYES Replacement PARTS, Service Handbooks and Training AidsSequence of Operation Flow Chart Complaint Cause User Serviceman Operational ChecklistLindahl Parkway Ashland City, TN Phone 800-821-2017 Fax