TWO TEMPERATURE - TWO HEATERS HIGH TEMPERATURE STORAGE

WITH OR WITHOUT RECIRCULATION

DANGER:

TEMPERATURE SETTING SHOULD NOT EXCEED SAFE TEMPERATURES AT FIXTURES. SEE WATER TEMPERATURE CONTROL WARNING ON PAGE 10. IF HIGHER PREHEAT TEMPERATURES ARE NECESSARY TO OBTAIN ADEQUATE BOOSTER OUTPUT, ADD AN ANTI-SCALD VALVE FOR HOT WATER SUPPLIED TO FIXTURES.

* PIPE RELIEF VALVE TO OPEN DRAIN

NOTE: IF TEMPERED WATER IS RECIRCULATED, RETURN LINE SHOULD BE CONNECTED AT POINT "A"

FOR MULTIPLE HEATER INSTALLATION SEE MANIFOLD KIT SPECIFICATIONS, PAGES 19.

INSET B

VACUUM RELIEF VALVE

INSTALL PER LOCAL CODES.

INSET A

INSTALL THERMAL EXPANSION TANK IN COLD WATER SUPPLY LINE, IF CHECK VALVE OR PRESSURE REDUCING VALVE IS USED IN SUPPLY.

INSTALL IN ACCORDANCE WITH LOCAL CODES

WIRING DIAGRAM FOR 180°F (82.2°C) LOOP (IF USED)

WIRING DIAGRAM FOR TEMPERED WATER LOOP

(IF USED)

16

Image 16
Contents Place These Instructions Adjacent to Heater Lindahl Parkway Ashland City, TNNotify Owner to Keep for Future Reference Features and Specifications Nominal Model DimensionsRecovery CAPACITIES, based on 80% efficiency GPOApprovals Table of ContentsIdentification Safety InstallationProper Installation on Combustible Flooring ClearancesCombustion and Ventilation AIR Chemical Vapor CorrosionVent Connector and Draft Regulator Proper Vent Connector InstallationFlue GAS Venting ChimneyDrain Valve and Access Panels Water PipingClosed Water System Fuel SystemsBurner Installation Typical Heater Installation FigureGravity FEED, Supply Line ONLY, Installation System TypesOIL Pump & Nozzle Specifications Assembly of the OIL Burner to the HeaterFuel Pump BurnerWater Temperature Control High Limit Switch E.C.OOperation FillingMaintenance Burner Certificate Combustion TestDraining Relief ValvesLime Scale Removal Sediment RemovalFlo-jug Method of Deliming Circulating Pump Soot RemovalVent System Anode ROD InspectionInstallation Diagrams Install in Accordance with Local CodesInset B Inset aSingle Temperature or Booster Inset B Install in Accordance with Local Codes Inset a Check List and Service Information Electrical Wiring ReplacementNot Enough or no HOT Water Manifold KIT Commercial OIL Fired Water HeatersBurner STARTS-WONT Operate Water is TOO HOTWater Heater Makes Sounds Water Leakage is SuspectedCombustion Test Specifications Normal START, but Locks OUT on SafetySafety Primary Control ProcedureTroubleshooting Item no Cleanout Assembly Lindahl Parkway, Ashland City, TN Phone 800-821-2017 FaxDescription