State Industries GPO 86-199 manual Description

Page 24

 

 

GPO 86

GPO 86

GPO 84

GPO 75

GPO 75

GPO 69

 

 

ITEM

DESCRIPTION

199

245

315

385(A)

455(A)

700(A)

 

 

 

 

 

 

 

 

1 ....

*Anode

183523-42(2) ...

183523-42(2)

183523-42(2)

....... 183523-39(3)

183523-39(3)

183523-39(4)

2 ....

Baffle, Flue

39616-13(6)

39616-13(6)

39616-13(7)

....... 39616-13 (12)

39616-13(12)

39616-13(16)

3 ....

Base, Jacket w/skids

76242

76242

76242

76242

76242

76242

4 ....

Bolt, Base

41431(4)

41431-(4)

41431-(4)

41431(4)

41431(4)

41431(4)

5 ....

Chamber, Combustion

76508-1

76508-1

76508-1

76508-1

76508-1

76508-1

6 ....

Channel, Wire

95312-4

95312-4

95312-4

95312-4

95312-4

95312-4

7 ....

Clamp

94694

94694

94694

94694

94694

94694

 

CLEANOUT ASSEMBLY

 

 

 

 

 

 

8 ....

Gasket

99038(1)

99038(1)

99038(1)

99038(2)

99038(2)

99038(2)

9 ....

Pressure Plate

99037(1)

99037(1)

99037(1)

99037(2)

99037(2)

99037(2)

10 ...

Screw-self Tapping

69852-1(6)

69852-1(6)

69852-1(6)

69852-1(12)

69852-1(6)

69852-1(6)

11 ...

Collar, Pipe

20172-21

20172-21

20172-21

20172-21

20172-21

20172-21

12 ...

Collar, Pipe

95030-3

95030-3

95030-3

95030-3

95030-3

95030-3

13 ...

Barometric Draft Control

69803

69803

69803

69803

69803

69803

14 ...

Cover, Cleanout Opening &

 

 

 

 

 

 

.....

Observation Port

181260

181260

181260

181260

181260

181260

15 ...

Cover, Jacket

97062

97062-4

97062-4

97062-4

97062-4

97062-1

 

*INSULATION,

 

 

 

 

 

 

 

FIBERGLASS SKIRT

 

 

 

 

 

 

 

Top

181268-14

181268-14

181268-14

181268-14

181268-14

181268-14

 

Bottom

181268-19

181268-19

181268-19

181268-19

181268-19

 

Insulation Skirt

- - - - - -

- - - - - -

- - - - - -

- - - - - -

191017-2

191017-2

16 ...

*LABELS

 

 

 

 

 

 

 

Cleanout

78754

78754

78754

78754

78754

78754

 

Combination

192485

192485

192485

192485

192485

192485

 

Copper Conductor

192495

192495

192495

192495

192495

192495

 

Hot

192484

192484

192484

192484

192484

192484

 

Relief Valve

191068

191068

191068

191068

191068

191068

 

UL

193657

193657-1

193657-2

193657-3

193657-4

193657-5

 

Inlet

94518

94518

94518

94518

94518

94518

 

Outlet

94519

94519

94519

94519

94519

94519

 

Wiring Diagram

193694

193694

193694

193695

193695

193695

17 ...

Gasket, Skirt Ring

76443

76443

76443

76443

76443

76443

18 ...

Insulation, Foil-Faced

41175

41175

41175

41175

41175

41175

19 ...

Jacket

193062

193062

193062

193064

193064

193066

20 ...

Plug, Observation

41377

41377

41377

41377

41377

41377

21 ...

Reducer, Flue

99767-2

- - - - - -

- - - - - -

- - - - - -

- - - - - -

76707-1

22 ...

Ring,Flue Collector

193022

193022

193022

193021

193021

193021

23 ...

Skirt Ring

193016

193016

193016

193016

193016

193016

24 ...

Valve, Drain

26273-4

26273-4

26273-4

26273-4

26273-4

26273-4

25 ...

Valve, Relief

99465-7

192467

192467

192467

192467

99465-3

26 ...

+WIRE:

 

 

 

 

 

 

 

16 AWG Stranded,

 

 

 

 

 

 

 

105°C, AWM & TEW:

 

 

 

 

 

 

 

Black

86578

86578

86578

86578

86578

86578

 

Red

86579

86579

86579

86579

86579

86579

 

White

86580

86580

86580

86580

86580

86580

 

Yellow

98199

98199

98199

98199

98199

98199

27 ...

*Instruction Manual

193472

193472

193472

193472

193472

193472

28 ...

Thermostat with E.C.O

192576

192576

192576

192576

192576

192576

29 ...

Oil Burner

 

 

 

 

 

 

 

Single Stage

193655

193655-2

193655-4

193656

193656-2

193656-4

 

Two Stage

193655-1

193655-3

193655-5

193656-1

193656-3

193656-5

* Not Illustrated

( ) Quantities shown in parenthesis next to part number.

+When ordering wire, indicate length required in inches. (Example: 86578-100 equals 100" Length.) Part numbers underlined are recommended stock items for emergency replacement.

Request parts from Product Service Division giving all information such as model and series number.

24

Image 24
Contents Lindahl Parkway Ashland City, TN Place These Instructions Adjacent to HeaterNotify Owner to Keep for Future Reference Features and Specifications Nominal Model DimensionsRecovery CAPACITIES, based on 80% efficiency GPOTable of Contents ApprovalsIdentification Safety InstallationProper Installation on Combustible Flooring ClearancesCombustion and Ventilation AIR Chemical Vapor CorrosionVent Connector and Draft Regulator Proper Vent Connector InstallationFlue GAS Venting ChimneyDrain Valve and Access Panels Water PipingClosed Water System Fuel SystemsBurner Installation Typical Heater Installation FigureGravity FEED, Supply Line ONLY, Installation System TypesOIL Pump & Nozzle Specifications Assembly of the OIL Burner to the HeaterFuel Pump BurnerWater Temperature Control High Limit Switch E.C.OOperation FillingMaintenance Burner Certificate Combustion TestDraining Relief ValvesSediment Removal Lime Scale RemovalFlo-jug Method of Deliming Circulating Pump Soot RemovalVent System Anode ROD InspectionInstallation Diagrams Install in Accordance with Local CodesInset B Inset aSingle Temperature or Booster Inset B Install in Accordance with Local Codes Inset a Check List and Service Information Electrical Wiring ReplacementNot Enough or no HOT Water Manifold KIT Commercial OIL Fired Water HeatersBurner STARTS-WONT Operate Water is TOO HOTWater Heater Makes Sounds Water Leakage is SuspectedCombustion Test Specifications Normal START, but Locks OUT on SafetySafety Primary Control ProcedureTroubleshooting Item no Cleanout Assembly Lindahl Parkway, Ashland City, TN Phone 800-821-2017 FaxDescription