State Industries GPO 86-199 manual Install in Accordance with Local Codes

Page 17

TWO TEMPERATURE - THREE HEATERS (TWO PRE-HEATERS/ONE BOOSTER)

WITH OR WITHOUT CIRCULATION

INSET A

INSTALL THERMAL EXPANSION

TANK IN COLD WATER SUPPLY

LINE, IF CHECK VALVE OR

PRESSURE REDUCING VALVE IS

USED IN SUPPLY.

DANGER:

TEMPERATURE SETTING SHOULD NOT EXCEED SAFE TEMPERATURES AT FIXTURES. SEE WATER TEMPERATURE CONTROL WARNING ON PAGE 10. IF HIGHER PREHEAT TEMPERATURES ARE NECESSARY TO OBTAIN ADEQUATE BOOSTER OUTPUT, ADD AN ANTI-SCALD VALVE FOR HOT WATER SUPPLIED TO FIXTURES.

INSET B

VACUUM RELIEF VALVE

INSTALL PER LOCAL CODES.

TWO TEMPERATURE - TWO HEATERS (ONE PRE-HEATER/ONE BOOSTER HEATER)

WITH OR WITHOUT RECIRCULATION

WIRING DIAGRAM FOR FIXTURE OR BOOSTER

LOOP (IF USED) - OTHER THAN DISHWASHER

WIRING DIAGRAM FOR 180° LOOP (IF USED)

INSTALL IN ACCORDANCE WITH LOCAL CODES

*PIPE RELIEF VALVE TO OPEN DRAIN

**140°F (60°C) TO 150°F (65.5°C) SHOULD BE MAXIMUM WATER TEMPERATURE MAINTAINED IN THE PRE-HEATERS.

120°F (48.8°C) SHOULD BE THE MINIMUM TEMPERATURE OF WATER STORED IN THE PRE-HEATERS.

CONNECT CIRCULATING LINE FROM FIXTURES, IF USED, TO COLD WATER SUPPLY LINE OF PRE-HEATER.

CONNECT CIRCULATING LINE OF 180°F OR BOOSTED WATER, IF USED, TO INLET WATER LINE TO BOOSTER.

17

Image 17 Contents
Notify Owner to Keep for Future Reference Lindahl Parkway Ashland City, TNPlace These Instructions Adjacent to Heater Nominal Model Dimensions Features and SpecificationsRecovery CAPACITIES, based on 80% efficiency GPOIdentification Table of ContentsApprovals Installation SafetyClearances Proper Installation on Combustible FlooringCombustion and Ventilation AIR Chemical Vapor CorrosionProper Vent Connector Installation Vent Connector and Draft RegulatorFlue GAS Venting ChimneyWater Piping Drain Valve and Access PanelsClosed Water System Fuel SystemsTypical Heater Installation Figure Burner InstallationGravity FEED, Supply Line ONLY, Installation System TypesAssembly of the OIL Burner to the Heater OIL Pump & Nozzle SpecificationsFuel Pump BurnerHigh Limit Switch E.C.O Water Temperature ControlOperation FillingBurner Certificate Combustion Test MaintenanceDraining Relief ValvesFlo-jug Method of Deliming Sediment RemovalLime Scale Removal Soot Removal Circulating Pump Vent System Anode ROD InspectionInstall in Accordance with Local Codes Installation DiagramsInset B Inset aSingle Temperature or Booster Inset B Install in Accordance with Local Codes Inset a Electrical Wiring Replacement Check List and Service InformationNot Enough or no HOT Water Manifold KIT Commercial OIL Fired Water HeatersWater is TOO HOT Burner STARTS-WONT OperateWater Heater Makes Sounds Water Leakage is SuspectedNormal START, but Locks OUT on Safety Combustion Test SpecificationsSafety Primary Control ProcedureTroubleshooting Lindahl Parkway, Ashland City, TN Phone 800-821-2017 Fax Item no Cleanout AssemblyDescription