England's Stove Works 10-CDV, 49-SHC22, 49-TRC22 operation manual Codes, SHUT-DOWN Procedure

Page 15

E-Codes

“E-Codes,” or Error Codes, are codes that will appear in the Heat Range and Blower Speed windows of the Control Board if your unit experiences problems. If you receive these codes, wait

until the unit is cooled completely down before trying to restart your unit.

If the unit continues to display any E-Code(s), please contact Customer Service at (800) 245-6489 before further attempting to restart your unit.

E-2= Fail to Start

NOTE: E-0 indicates “No Error”

First Fire: When you push the “ON” button, the Control Board will automatically be set at both “Heat Range” and “Blower Speed” to setting “5”. Allow the stove to burn in this manner for at least three (3) hours. This will allow the unit to “cure out” as the paint and the oils from the manufacturing process burn off. We recommend you open doors and windows in your dwelling during this process.

Subsequent Cold Starts: In a cold start situation, the unit should be operated at a “5” setting until the room air blower begins to operate.

NOTE: Press the “ON” button only once on start-up. Pressing the “ON” button a second time during the start-up cycle will cause the start-up cycle to begin again.

IMPORTANT: If the unit fails to start properly, or does not properly complete the Shut-Down procedure, open the closest outside door and a window to eliminate the home’s natural draft BEFORE opening the stove’s door or hopper lid. This will allow any smoke to exit through the external air hook-up instead of spilling into the home.

SHUT-DOWN PROCEDURE

WARNING: NEVER SHUT DOWN THIS UNIT BY UNPLUGGING IT FROM THE POWER SOURCE.

Refer to the following instructions:

Press the “OFF” touch pad to put the stove in the “Shut-Down” mode. There will be an “S D” in the Heat Range and Blower Speed windows while the unit is shutting down to verify this. At this time the red light above the “OFF” pad will illuminate. When the “OFF” pad is touched the auger will instantly stop feeding fuel to the auger tube, but the room air blower, exhaust blower and bottom auger will continue to operate. When the internal temperature drops to 95 degrees the room air blower will cease to operate, and when the internal temperature drops to 90 degrees the exhaust blower will stop. The red light will then shut off and the entire stove will be shut down. The hotter the unit is operating, the longer it will take for the stove to complete the Shut-Down cycle.

Note: The unit will exit the Shut-Down cycle if you press any buttons during Shut-Down.

Note: If the room temperature stays above 70 degrees the stove will remain in the Shut Down mode for 60 minutes, regardless of the temperature reading at the heat sensor. If the stove stays on longer than 60 minutes the unit will automatically turn off.

NOTE: If your unit overheats the auger will stop feeding and the unit will go into Shut-Down if it does not recover; if this happens you need to wait 45 minutes before trying to re- light the unit.

15

Image 15
Contents Must be maintained Model Numbers 10-CDV 49-TRC22 49-SHC22Wishing you years of efficient, quality and comfy heating Important Information Important Notice Important Information Read Before Operating Unit PreparationPage Page Do not Connect to ANY AIR Distribution Duct or System Setting the Stirrer Burning Solid FuelsWood Pellets Be sure to check local codes in your area Flue SystemMobile Home Installation Through the CeilingOutside Air Outside Combustion Air Intake Floor and Wall Protection Floor ProtectionWall Protection Operating Instructions START- UP ProceduresCorn START-UP Procedure Pellet START-UP ProcedureTo remove the stirrer for burning pellets Codes SHUT-DOWN ProcedureDaily Operation Annual Cleaning ASH Removal and DisposalAsh Pan Semi-Weekly Ash Removal Maintenance Auger Removal and Replacement FinishGlass Recommended Heat Ranges Control BoardComponent Operation Start Operation END Circuit Board FunctionsAC-118, AC-118BN Window Trim Accessory ItemsThermostat AC-117, AC-117BN Lip TrimBox Parts Orders only Monroe, VA Questions Fax Replacement PARTS, Accessories and OptionsCustomer Service Department OptionsCorn Stove Exploded View Diagram Illustration Adjusting your Hopper Lid Latch Directions for Installation Legs or Pedestal Dimensions of your corn/pellet unitProblem Cause Solution TROUBLE-SHOOTING GuideProblem Warranty is not Transferable Page Unit Information Dealer Information