England's Stove Works 49-TRC22, 10-CDV, 49-SHC22 Control Board, Recommended Heat Ranges

Page 20

Control Board

The Control Board (Part # CU-CB05) is a digital read-out board. This board offers a wide variety of settings to operate the unit. This part can be removed from the unit by loosening the two outside screws and pulling the board back to the inside of the stove. The rear access panel should be removed prior to removing the control board. A 6-amp “quick-blow” fuse is used on this Control Board.

NOTE: The bottom three control buttons are preset at the factory and should not require any changes. See “Operating Instructions” and “Daily Operation” section of the manual for instructions on other Control Board settings.

 

Recommended Heat Ranges:

 

Low Burn:

Heat Range setting:

1

 

Room Air Blower setting:

1

Medium Low:

Heat Range setting: 2

– 3

Room Air Blower setting: *

Medium High:

Heat Range setting:

4

– 8

Room Air Blower setting: *

High Burn:

Heat Range setting:

9

 

Room Air Blower setting:

9

* NOTE: Blower Speed will automatically be adjusted to the desired Heat Range that you select.

CAUTION:

NOTE: The bottom

3buttons are pre-set at the factory and do not need adjustment.

Call Customer Service at (800) 245-6489 if you have questions or problems.

Illustration 4

Control Board Diagram

CAUTION: Moving Parts May Cause Injury.

Do NOT Operate with Panel(s) Off.

DANGER: Parts May Be Hot. Risk of Electric Shock.

Disconnect Power Before Servicing Unit.

20

Image 20
Contents Model Numbers 10-CDV 49-TRC22 49-SHC22 Must be maintainedWishing you years of efficient, quality and comfy heating Important Information Important Notice Unit Preparation Important Information Read Before OperatingPage Page Do not Connect to ANY AIR Distribution Duct or System Wood Pellets Setting the StirrerBurning Solid Fuels Flue System Be sure to check local codes in your areaOutside Air Outside Combustion Air Intake Mobile Home InstallationThrough the Ceiling Wall Protection Floor and Wall ProtectionFloor Protection START- UP Procedures Operating InstructionsTo remove the stirrer for burning pellets Corn START-UP ProcedurePellet START-UP Procedure SHUT-DOWN Procedure CodesDaily Operation Ash Pan Semi-Weekly Ash Removal Annual CleaningASH Removal and Disposal Maintenance Glass Auger Removal and ReplacementFinish Control Board Recommended Heat RangesCircuit Board Functions Component Operation Start Operation ENDAccessory Items ThermostatAC-117, AC-117BN Lip Trim AC-118, AC-118BN Window TrimReplacement PARTS, Accessories and Options Customer Service DepartmentOptions Box Parts Orders only Monroe, VA Questions FaxCorn Stove Exploded View Diagram Illustration Adjusting your Hopper Lid Latch Dimensions of your corn/pellet unit Directions for Installation Legs or PedestalTROUBLE-SHOOTING Guide Problem Cause SolutionProblem Warranty is not Transferable Page Dealer Information Unit Information