England's Stove Works 10-CDV Circuit Board Functions, Component Operation Start Operation END

Page 21

Illustration 5

CU-CB05

Control Board

Diagram (Wiring)

CIRCUIT BOARD FUNCTIONS

COMPONENT

OPERATION START

OPERATION END

 

Exhaust Blower

Starts Immediately

Will continue until shutdown.

Shutdown will

 

 

occur when the operating temp. is below 90

 

 

degrees.

 

Agitator

Three minutes after starting, the agitator

Will continue intermittently, as determined by the

 

will begin to turn.

Heat Setting, until Shutdown

 

Auger

Three minutes after starting, the auger

The auger will continue at the feed rate

 

will begin to turn.

determined by the Heat Setting.

NOTE: Safety

 

 

switch, Hi Limit and Vacuum Sensor much be

 

 

activated to continue proper operation.

Room Fan

Begins when 110 degrees is reached

Will continue to operate until the unit cools down

 

 

to below 90 degrees. This may take from

 

 

several minutes up to an hour.

 

Automatic

If, after 15 minutes, the unit has not

If the timer should expire before the preset

Shutdown

reached the preset operating temp., the

operating temp. is achieved, resetting the timer

 

unit will begin to automatically shut

is possible by switching the Control Board “OFF”

 

down. This will be evidenced by the red

and then back “ON.”

 

 

light on the Control Board.

 

 

Normal Operation

If, after 15 minutes, the preset operating

Operation will continue until either the Control

 

temp. of 110 degrees is achieved,

Board is turned “OFF,” or the operating temp.

 

normal operation will continue.

falls to below 90 degrees. At this time, the unit

 

 

will default to “Automatic Shutdown.”

21

Image 21
Contents Must be maintained Model Numbers 10-CDV 49-TRC22 49-SHC22Wishing you years of efficient, quality and comfy heating Important Information Important Notice Important Information Read Before Operating Unit PreparationPage Page Do not Connect to ANY AIR Distribution Duct or System Setting the Stirrer Burning Solid FuelsWood Pellets Be sure to check local codes in your area Flue SystemMobile Home Installation Through the CeilingOutside Air Outside Combustion Air Intake Floor and Wall Protection Floor ProtectionWall Protection Operating Instructions START- UP ProceduresCorn START-UP Procedure Pellet START-UP ProcedureTo remove the stirrer for burning pellets Codes SHUT-DOWN ProcedureDaily Operation Annual Cleaning ASH Removal and DisposalAsh Pan Semi-Weekly Ash Removal Maintenance Auger Removal and Replacement FinishGlass Recommended Heat Ranges Control BoardComponent Operation Start Operation END Circuit Board FunctionsThermostat Accessory ItemsAC-117, AC-117BN Lip Trim AC-118, AC-118BN Window TrimCustomer Service Department Replacement PARTS, Accessories and OptionsOptions Box Parts Orders only Monroe, VA Questions FaxCorn Stove Exploded View Diagram Illustration Adjusting your Hopper Lid Latch Directions for Installation Legs or Pedestal Dimensions of your corn/pellet unitProblem Cause Solution TROUBLE-SHOOTING GuideProblem Warranty is not Transferable Page Unit Information Dealer Information