Enviro 1700 Insert, C-11116, 1200 Insert, 1700 Fireplace Freestanding Any area within 10 feet

Page 26

 

 

 

 

 

 

 

 

Installation

 

and in any area within 10 feet

 

 

 

Rain cap/

(304.8 cm) of the roof ridge,

 

 

 

 

 

 

Spark arrestor cap

 

 

 

 

 

 

 

 

 

 

 

the chimney must be 2 feet

 

 

Roof radiation

Storm Collar

(60.9

cm)

above

the

ridge.

 

 

Roof flashing

Refer to Figure 24.

 

 

 

shield (if required)

 

 

 

 

 

Roof

Note:

Increasing

the

chimney

 

 

 

 

Insulated chimney

 

height above the roof may

 

 

help your unit to draft better.

 

 

 

 

This greater draft can decrease

 

 

 

 

problems

such

 

as

difficult

Ceiling

Minimum

Minimum air space

start-ups, smoke

coming out

 

18" (475 mm)

 

in accordance with

when door is open, and dirty

 

 

 

chimney manufacturer.

 

 

 

 

glass. You may initially try

 

 

 

Insulated corner

the minimum required height

 

 

 

and if problems do arise, add

 

 

 

 

additional height later.

 

 

 

Chimney

Wall support

10. Slide the

roof

flashing

over

 

 

connector

Chase

your chimney and seal the

 

 

 

 

 

 

(optional)

flashing to the

roof

with a

Woodstove

Optional

 

roofing compound. Secure the

fan

 

 

 

 

roof flashing to your roof with

 

 

 

 

nails or screws.

 

 

 

 

 

Pedestal

 

 

11. Place the storm collar over the

Hearthpad

 

 

flashing and seal the joints

 

 

 

 

with silicone caulking.

 

 

 

 

 

 

12. Fasten

the

rain

cap

/

spark

Floor

Outside air connection

 

arrestor cap to the top of your

 

 

through wall or floor

 

chimney.

 

 

 

 

 

Figure 26: Standard Horizontal Installation.

13. Place

the

stove

back

into

 

 

 

 

position.

 

 

 

 

 

 

 

 

 

14.Install the chimney connector pipe with the lower (crimped) edge of the pipe inside the flue collar. Any creosote formed will then run back down into the stove. All connections must be tight and secured with three sheet metal screws equally spaced. Double wall pipe is recommended over single wall.

15.Also install an outside air flex pipe to the stove.

IMPORTANT: When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be followed. You must also purchase and install the ceiling support package or wall pass-through and “T” section package, firestops (where needed), insulation shield, roof flashing, chimney cap, etc. Maintain proper clearance to the structure as recommended by the manufacturer. The chimney must be the required height above the roof or other obstructions for safety and proper draft operation.

Note: If you are using a horizontal connector (refer to Figure 26), the chimney connector should be as high as possible while still maintaining the 18” (475 mm) minimum distance from the horizontal connector to the ceiling.

26

Image 26
Contents Wood Stove Table of Contents Safety Precautions Operating Instructions First StartReplacing the Glass Maintenance Helpful Hints Worth Repeating What does dry, seasoned wood mean? Air Control Rod 1200 Air Flow Path Specifications Capacity Feet3 0.0708 meter3 Approximate heating area † From front of door opening to edge of floor protection Maintain These Minimum Clearances to Unshielded Combustibles 1700 Freestanding Clearance to Combustibles 1200 Insert Dimensions 1700 Insert Dimensions 1200 Freestanding Flat Top Dimensions 1700 Freestanding Flat Top Dimensions 1200 Freestanding with Fan Kit Dimensions Installation Bolts to removeInstalling Heat Shield Recommended Height for Flue Pipe Chimney Through Wall Method a Roof Clearances Any area within 10 feet Installation into a masonry chimney Venting Outside AIR Insert Installation into existing fireplace with Hearth Metal TAG this Fireplace has Been Before starting this type of installation 3D of Dimensions needed from Fireplace Insert Install into a Zero-Clearance Fireplace Total Bricks Tube C Tube B Tube a Do not USE Door if Glass is Broken Installation of Ceramic Baffle Back View of Freestanding Unit with Fan Kit Removal of right Pod Installation of Trim Parts List EFW-264 PartsDiagramFreestanding Parts Diagram Pedestals & Legs Parts Diagram Fireplace Insert Warranty Limited Five 5 Year Warranty Limited One 1 Year WarrantyExclusions and Limitations Warranty Installation Data Sheet