Enviro 1700 Insert, C-11116, 1200 Insert, 1700 Fireplace Freestanding Installation of Trim

Page 41

Installation

INSTALLATION OF THE SURROUND PANEL - INSERT:

Installation of Trim:

The trim set for your surround panel must be installed before installing the surround panel onto the unit, if not already done.

1.Attach one side trim to the top trim, using a corner bracket (see Figure 53) to secure pieces together. There are two (2) main pieces to each corner bracket (see

Figure 54). When installing the corner pieces into the trim, the “B FACE” sides must face each other

Figure 53: Corner brackets for trim. and the screw heads are to face

out. With the bracket in place and

the top and a side trim snug together, use

 

a flat head screwdriver to turn the two (2)

 

Figure 54: Two pieces of corner

screws in the bracket to tighten it into the

bracket.

trim.

 

Figure 55: Screw to hold the trim against the sur- round.

3.Slide the two (2) attached trim pieces onto the surround panel.

4.Attach the other side trim piece to the top trim, using the same method used in Step 1.

5.Place the second side of the trim on the surround panel in the same manner used on the first side and secure in the same manner.

6.On the side trims, there are holes 2” (50 mm) from either end. Use a Phillips screwdriver to place a #8 screw 11⁄4” long in each hole and tighten (refer to Figure 55). This will keep the

trim tight against the surround.

Installation of Surround Panel onto Unit:

There are two (2) hooks on either side of the inside of the panel. Line up the openings on the hooks with the screws on the outside of either shroud (see Figure 56). Push the surround in and push it down into place.

Figure 56: Installation of Panel.

41

Image 41
Contents Wood Stove Table of Contents Safety Precautions First Start Operating InstructionsReplacing the Glass Maintenance Helpful Hints Worth Repeating What does dry, seasoned wood mean? Air Control Rod 1200 Air Flow Path Specifications Capacity Feet3 0.0708 meter3 Approximate heating area † From front of door opening to edge of floor protection Maintain These Minimum Clearances to Unshielded Combustibles 1700 Freestanding Clearance to Combustibles 1200 Insert Dimensions 1700 Insert Dimensions 1200 Freestanding Flat Top Dimensions 1700 Freestanding Flat Top Dimensions 1200 Freestanding with Fan Kit Dimensions Bolts to remove InstallationInstalling Heat Shield Recommended Height for Flue Pipe Chimney Through Wall Method a Roof Clearances Any area within 10 feet Installation into a masonry chimney Venting Outside AIR Insert Installation into existing fireplace with Hearth Metal TAG this Fireplace has Been Before starting this type of installation 3D of Dimensions needed from Fireplace Insert Install into a Zero-Clearance Fireplace Total Bricks Tube C Tube B Tube a Do not USE Door if Glass is Broken Installation of Ceramic Baffle Back View of Freestanding Unit with Fan Kit Removal of right Pod Installation of Trim Parts List EFW-264 PartsDiagramFreestanding Parts Diagram Pedestals & Legs Parts Diagram Fireplace Insert Limited Five 5 Year Warranty Limited One 1 Year Warranty WarrantyExclusions and Limitations Warranty Installation Data Sheet