Installation
INSTALLATION USING A
If this unit is to be installed into a masonry fireplace or a
1.Determine where the
is level and in an area where the plate can be mounted easily.
The measurement that will be needed are as followed (refer to Figure 38 and 39):
A - The width at the front of the firebox at the height where the
B - The width at the back of the firebox at the height where the
C - Then depth of the
D - The distance of the center of the flue to the front of the fireplace opening. Refer to Step 3.
NOTE: In general masonry fireplaces have square fireboxes while
2.Create a cardboard template of the dimensions with 2” (51 cm) wide flanges on each side. These flanges will be used to mount the
3.With the template in place, mark the location for the center of the flue pipe when the unit is in place. If installing a 1200 the distance will be approximately 81⁄4” or 9 15/16” back from the fireplace opening. If installing a 1700 the distance will be approximately 123⁄4” or 14 7/16” back from the fireplace opening. Remove the template and cut a 61⁄4” diameter hole centered on this mark.
4.Using the template make the
Figure 38: 3D of Dimensions needed from
the Fireplace.
B |
C |
D |
A |
Front of fireplace opening. |
Figure 39: Layout of the Block-Off Plate.
33