Enviro 1200 Insert, C-11116, 1700 Insert owner manual Do not USE Door if Glass is Broken

Page 37

Installation

DOOR INSTALLATION:

Please inspect all components for damage. If damage has occurred, please contact the courier company, dealer, or distributor and have components repaired or replaced before installation. Remove the door from the packaging. Inspect the door assembly for damage.

1. Install door handle as shown in Figure 44.

Nut

Cast Latch

Washer (x2)

Spring Washer

Furel

Handle

Figure 45: Installation Door onto Unit.

Figure 44: Installation Door Handle

Hardware.

2.Place the door assembly on the two (2) hinge pins mounted on the body of the unit. Refer to Figure 45.

3.Open and close the door, applying pressure down, to ensure the door assembly is properly seated on the hinges. Refer to Figure 46.

4.Please clean all fingerprints off of all plated surfaces, with denatured alcohol on a soft cloth, before firing the unit each time. Fingerprints, etc., can become permanently etched into the plating if not removed before operating the stove.

NOTE: When the door is installed on the unit and the handle closed, ensure that the spring handle is at the 4:00 position.

Close the door

assembly and

turn the door

handle

downwards

until door is

tight.

Thread slider

damper handle

onto slider damper

control on the side

of the unit.

Figure 46: Closing Door.

DO NOT USE DOOR IF GLASS IS BROKEN.

37

Image 37
Contents Wood Stove Table of Contents Safety Precautions First Start Operating InstructionsReplacing the Glass Maintenance Helpful Hints Worth Repeating What does dry, seasoned wood mean? Air Control Rod 1200 Air Flow Path Specifications Capacity Feet3 0.0708 meter3 Approximate heating area † From front of door opening to edge of floor protection Maintain These Minimum Clearances to Unshielded Combustibles 1700 Freestanding Clearance to Combustibles 1200 Insert Dimensions 1700 Insert Dimensions 1200 Freestanding Flat Top Dimensions 1700 Freestanding Flat Top Dimensions 1200 Freestanding with Fan Kit Dimensions Bolts to remove InstallationInstalling Heat Shield Recommended Height for Flue Pipe Chimney Through Wall Method a Roof Clearances Any area within 10 feet Installation into a masonry chimney Venting Outside AIR Insert Installation into existing fireplace with Hearth Metal TAG this Fireplace has Been Before starting this type of installation 3D of Dimensions needed from Fireplace Insert Install into a Zero-Clearance Fireplace Total Bricks Tube C Tube B Tube a Do not USE Door if Glass is Broken Installation of Ceramic Baffle Back View of Freestanding Unit with Fan Kit Removal of right Pod Installation of Trim Parts List EFW-264 PartsDiagramFreestanding Parts Diagram Pedestals & Legs Parts Diagram Fireplace Insert Limited Five 5 Year Warranty Limited One 1 Year Warranty WarrantyExclusions and Limitations Warranty Installation Data Sheet