Initial Installation

QUALIFIED INSTALLERS ONLY

CONVERTING A DIRECT VENT FIREPLACE TO A B-VENT FIREPLACE:

1.Remove the Direct Vent chimney connector assembly by taking out the two (2) T-20 screws at the front of the unit. Push the assembly out from under the brackets at the back and remove (see Figure 16).

2.Remove the two (2) fresh air inlet covers from each side. Cover locations shown in Figure 16.

3.Slide the B-Vent chimney connector assembly into the same position the Direct Vent chimney connector assembly was in. Ensure the tabs are under the brackets at the back and the holes at the front line up. Secure into place with the two (2) T-20 screws at the front of the unit.

4.Disconnect the two (2) blue wires at the opening to the right of the unit and connect them to the 300°F (149°C) manual reset spill switch at the rear of the B-Vent chimney connector with the wires supplied. Refer to Figure 17.

5.Test fire the appliance and ensure proper operation. A venturi adjustment could be required to achieve an efficient flame. Improper operation or adjustment could result in Carbon Monoxide production causing personal injury or property damage.

Direct Vent

Connector Assembly

Fresh Air

Inlet Covers

Figure 16: Converting to a BV fireplace.

B-Vent

Connector Assembly

300°F (149°C)

manual reset

spill switch

Figure 17: Converting to a BV fireplace.

17

Image 17
Contents What to do if YOU Smell GAS General Safety PrecautionsFor Your Safety Table of Contents Vented GAS Fireplace Heater Sienna BV/DV NG/LPG Codes And ApprovalsRating Label Location SpecificationsDimensions 33 x 46 84cm x 193 cm Pilot Light Operating InstructionsPilot Lighting Instructions Burner Lighting Remote Controls OptionalTurn OFF Unit Blower SpeedCleaning the Glass Maintenance And ServiceCleaning the Firebox Cleaning the Plated SurfacesFuel Conversion To be Installed by a Qualified Service Agency onlyClearances to Combustibles Initial InstallationMinimum Fireplace Size Vent Model Automatic Flue GAS Spill Switch B-VENT Model onlyDirect Vent Model Preparing Your Sienna for InstallationVenting Fireplace Inserts Installation of Sienna DV and BVElectrical Requirements Prong from this plugGAS Line Connection Gas Line ConnectionConverting to a BV fireplace Converting a Direct Vent Fireplace to a B-VENT FireplaceReplacing the Blower Secondary InstallationDoor Removal Installation of Surround PanelEmpty firebox with grate and locator pins LOG SET and Ember InstallationThird Stage Log Set Installation Never operate the fireplace with the glass door removed Adjusting Venturi AIR SettingsRemoving the Brick Panel Brick panel set is fragile, handle with extreme careBV only Trouble ShootingNumber Parts List- Unit ComponentsComponentsDiagramParts Parts Diagram Burner Parts List Options Parts Diagram Options To the Dealer WarrantyInstallation Data Sheet