Enviro C-10637, 50-1096 owner manual Never operate the fireplace with the glass door removed

Page 22

Secondary Installation

Figure 30. Sienna complete log set-up with embers burning.

NOTE: While the glass is still removed, it is recommended that the gas line be purged by lighting the pilot.

When lighting the fireplace for the first time since the log set and embers have been installed/replaced, watch for ignition at ALL the burner ports. If a long delay is noticed, turn the appliance off and wait for it to cool down. Remove the glass and rearrange the ember material, making sure none of the burner ports air holes are blocked.

Never operate the fireplace with the glass door removed.

ADJUSTING VENTURI AIR SETTINGS:

There is one venturi adjustment.

Use this venturi adjustment lever, shown in Figure 31,

to achieve a proper and efficient flame.

Adjust lever until the flame pattern is similar to Figure

30. Suggested pull out distances are 1⁄2” (13 mm) minimum for Natural Gas and 7⁄8” (22 mm) minimum for Propane.

Pull out the venturi adjustment to increase primary air at the venturi tube.

Push in the venturi adjustment to decrease primary air at the venturi tube.

Figure 31: Adjusting the venturi air setting.

22

Image 22
Contents What to do if YOU Smell GAS For Your Safety Safety PrecautionsGeneral Table of Contents Codes And Approvals Vented GAS Fireplace Heater Sienna BV/DV NG/LPGDimensions SpecificationsRating Label Location 33 x 46 84cm x 193 cm Pilot Lighting Instructions Operating InstructionsPilot Light Turn OFF Unit Remote Controls OptionalBurner Lighting Blower SpeedCleaning the Firebox Maintenance And ServiceCleaning the Glass Cleaning the Plated SurfacesTo be Installed by a Qualified Service Agency only Fuel ConversionInitial Installation Clearances to CombustiblesVent Model Automatic Flue GAS Spill Switch B-VENT Model only Minimum Fireplace SizePreparing Your Sienna for Installation Direct Vent ModelInstallation of Sienna DV and BV Venting Fireplace InsertsProng from this plug Electrical RequirementsGas Line Connection GAS Line ConnectionConverting a Direct Vent Fireplace to a B-VENT Fireplace Converting to a BV fireplaceSecondary Installation Replacing the BlowerInstallation of Surround Panel Door RemovalLOG SET and Ember Installation Empty firebox with grate and locator pinsThird Stage Log Set Installation Adjusting Venturi AIR Settings Never operate the fireplace with the glass door removedBrick panel set is fragile, handle with extreme care Removing the Brick PanelTrouble Shooting BV onlyParts List- Unit Components NumberComponentsDiagramParts Parts Diagram Burner Parts List Options Parts Diagram Options Warranty To the DealerInstallation Data Sheet