Enviro 50-1096, C-10637 owner manual Operating Instructions, Pilot Lighting Instructions

Page 7

Operating Instructions

For Your Safety, Read Safety Precautions And

Lighting Instructions Before Operating

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE.

PILOT LIGHTING INSTRUCTIONS:

CAUTION: Hot while operating. Do not touch, severe burns may result. Keep children, clothing, furniture, gasoline or other flammable vapors away.

CAUTION: Do not operate this fireplace with the glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified person! This appliance needs fresh air for safe operation and must be installed with provisions for combustion and ventilation air. See installation and operating instructions manual. Keep burner and control compartment clean.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage, or loss of life. Refer to owner's information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier. See installation and operating instructions accompanying appliance. Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING

PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A)This appliance is equipped with a pilot, which must be lit by hand by following these instructions exactly.

B)BEFORE LIGHTING smell all around the appliance area for gas and next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance. Do not touch any electrical switch: do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas suppliers instructions. If you cannot reach your gas supplier, call the fire department.

C)Use only your hand to push in or turn the gas control knob; NEVER use tools. If the knob will not push in or turn by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D)Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this label.

2.Turn off all electrical power to this appliance.

3.Turn off the gas control knob clockwise to the off position.

4.Open door. Wait fIve (5) minutes to clear out any gas. Close door. If you smell gas STOP! Follow “B” in the above safety information. If you do not smell gas go to the next step.

5.Find pilot-located to the left under the front log. Turn the gas control

knob counter-clockwise

to “PILOT”. Push the gas control in fully

and hold, keep knob depressed for about 30 seconds after

 

 

 

 

the pilot is lit. Release knob. If pilot goes out, repeat

 

 

 

 

 

 

 

 

steps 4 through 5.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING: this gas valve has a lockout device, which will not allow the pilot burner to be relit until the thermocouple has cooled. If the knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot does not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.

6. Turn the gas control knob counter clockwise to the “ON” position. Flip the burner switch to “ON” THEN TURN THE “HI/LOW”

knob to the desired setting.

TP

 

OUT

IN

7. Turn on the electrical power to the unit.

TH

 

O

 

 

TP

IH

L

OFF

 

 

 

 

 

 

 

 

P

 

TH

 

 

I

 

 

 

L

 

 

 

 

TO

 

 

 

 

NO

 

 

P

 

 

 

 

TO LI

 

 

TO TURN OFF GAS TO APPLIANCE

1. Flip burner switch to “OFF”

 

3. Turn off all electrical power to the appliance if service is to be performed.

2. Turn the gas control knob clockwise

to the “OFF” position.

�������

 

 

Figure 3. Lighting instruction label.

PILOT LIGHT:

1.Turn off the gas to the fireplace. If not recently done, remove the glass and let the unit air out for at least five (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints with soapy water. NEVER USE AN OPEN FLAME FOR LEAK TESTING.

2.Start the pilot by pressing the gas control knob and turning it to PILOT. While holding the gas control knob in, press the piezo ignitor several times until the pilot light starts. Hold the gas control knob in for 30 seconds. Check that the pilot has fully engulfed the thermocouple assembly (see Figure 4).

3.Start the main burner by turning the gas control knob to ON and then turn the rocker switch to ON. Check that all burner ports have flame.

4.Leak test all gas joints again.

����������

������������

Figure 4. Pilot flame.

7

Image 7
Contents What to do if YOU Smell GAS For Your Safety Safety PrecautionsGeneral Table of Contents Vented GAS Fireplace Heater Sienna BV/DV NG/LPG Codes And ApprovalsDimensions SpecificationsRating Label Location 33 x 46 84cm x 193 cm Pilot Lighting Instructions Operating InstructionsPilot Light Blower Speed Remote Controls OptionalBurner Lighting Turn OFF UnitCleaning the Plated Surfaces Maintenance And ServiceCleaning the Glass Cleaning the FireboxFuel Conversion To be Installed by a Qualified Service Agency onlyClearances to Combustibles Initial InstallationMinimum Fireplace Size Vent Model Automatic Flue GAS Spill Switch B-VENT Model onlyDirect Vent Model Preparing Your Sienna for InstallationVenting Fireplace Inserts Installation of Sienna DV and BVElectrical Requirements Prong from this plugGAS Line Connection Gas Line ConnectionConverting to a BV fireplace Converting a Direct Vent Fireplace to a B-VENT FireplaceReplacing the Blower Secondary InstallationDoor Removal Installation of Surround PanelEmpty firebox with grate and locator pins LOG SET and Ember InstallationThird Stage Log Set Installation Never operate the fireplace with the glass door removed Adjusting Venturi AIR SettingsRemoving the Brick Panel Brick panel set is fragile, handle with extreme careBV only Trouble ShootingNumber Parts List- Unit ComponentsComponentsDiagramParts Parts Diagram Burner Parts List Options Parts Diagram Options To the Dealer WarrantyInstallation Data Sheet