Figure 23: Filler panel with trim installation.
Figure 22: Screw to hold the trim against the surround.

Secondary Installation

DOOR REMOVAL:

Figure 19: Top bolts for glass door.

Open the door by removing the two (2) 5/16’’ bolts located at the top outside corners of the glass frame (see Figure 19). Lift the bottom of the door up and remove from unit (see Figure 20).

CAUTION GLASS MAY

SEPARATE FROM DOOR.

Figure 20: Bottom hooks for glass

door.

INSTALLATION OF SURROUND PANEL:

The Sienna must have one of the panels installed around the unit; the unit panel, the filler panel, or the filler panel with trim. If you have trim for your filler panel, the trim must be installed before installing the filler panel onto the unit.

1. Attach one side trim to the top trim using a corner bracket (see Figure 21) to secure pieces together.

There are two (2) main pieces to each corner bracket. When installing the corner pieces into the trim the “B FACE” sides must face each other and the screw heads are to face out. With the bracket in place and the top and a side trim snug together use a flat head screwdriver to turn the two (2) screws in the bracket in to tighten it into the trim.

2.Slide the two (2) attached trim pieces onto the surround panel.

3.Attach the other side trim piece to the top trim using the same method used in Step 1.

4.Place the second side of the trim on the surround panel in the same manner use on the first side and secure in the same manner.

5.On the side trims there are holes 2” (50 mm) from either end. Using a Phillips screwdriver to place a #8 screw 11⁄4”

long in each hole and tighten (refer to Figure

22). This will keep the trim tight against the surround.

To install the panel, lift the panel upright in front of the fireplace with the four (4) hooks pointing towards the fireplace. Slide the hooks into their corresponding slots (see Figure 23). Ensure the hooks are pushed all the way into the slots and the notch on the hook must be on the bottom of the slot. The panels should be wiped with a damp cloth periodically.

Figure 21: Corner brackets

for trim.

19

Image 19 Contents
What to do if YOU Smell GAS For Your Safety Safety PrecautionsGeneral Table of Contents Vented GAS Fireplace Heater Sienna BV/DV NG/LPG Codes And ApprovalsDimensions SpecificationsRating Label Location 33 x 46 84cm x 193 cm Pilot Lighting Instructions Operating InstructionsPilot Light Blower Speed Remote Controls OptionalBurner Lighting Turn OFF UnitCleaning the Plated Surfaces Maintenance And ServiceCleaning the Glass Cleaning the FireboxFuel Conversion To be Installed by a Qualified Service Agency onlyClearances to Combustibles Initial InstallationMinimum Fireplace Size Vent Model Automatic Flue GAS Spill Switch B-VENT Model onlyDirect Vent Model Preparing Your Sienna for InstallationVenting Fireplace Inserts Installation of Sienna DV and BV Electrical Requirements Prong from this plugGAS Line Connection Gas Line ConnectionConverting to a BV fireplace Converting a Direct Vent Fireplace to a B-VENT FireplaceReplacing the Blower Secondary InstallationDoor Removal Installation of Surround PanelEmpty firebox with grate and locator pins LOG SET and Ember InstallationThird Stage Log Set Installation Never operate the fireplace with the glass door removed Adjusting Venturi AIR SettingsRemoving the Brick Panel Brick panel set is fragile, handle with extreme careBV only Trouble ShootingNumber Parts List- Unit ComponentsComponentsDiagramParts Parts Diagram Burner Parts List Options Parts Diagram Options To the Dealer WarrantyInstallation Data Sheet