14
INSTALLING HEATER
Continued
INSTALLING RADIANTS
WARNING
WARNING ICON | G 001 |
Carefully handle the glass panel. Glass edges are rounded and buffed to prevent cuts, however, chipped or broken sections of glass can present sharp edges. These sharp edges can cut skin.
1.Remove glass guard from across opening at front of heater (see Figure 9).
2.Place radiants into combustion chamber through opening at front of heater. Front of radiant sits on front radiant support (see Figure 10). Back of radiant rests on back radiant support (see Figures 9 and 10).
Note: Radiants should never come in contact with burner flame. Contact with flame may cause carbon or soot deposits on radiants.
Burner
Glass
Guard
| Combustion | |
| Chamber | |
| Back Radiant | |
| Support | |
Lower | Lower Front | |
Access Area | ||
| ||
Front Access | ||
Panel | Glass Retaining | |
Channel | ||
| ||
| Figure 9 - Location of Radiants | |
| Back Radiant Support | |
| Radiant |
Burner
Front Radiant Support
Figure 10 - Position of Radiant
100791