Desa GVR50PA, GVR65PA, GVR65BPA, GVR35PA, GVR50BPA Parts List Burner Assembly for Radiant Models

Page 41

PARTS LIST Burner Assembly for Radiant Models

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Ordering Replacement Parts on page 36 of this manual.

 

 

 

PART NUMBER FOR

 

 

 

KEY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO.

GVR65BPA

GVR65PA

 

GVR50BPA

GVR50PA

GVR35PA

DESCRIPTION

QTY.

 

 

 

 

 

 

 

 

 

1

100729-03

100729-03

 

100729-02

100729-02

100729-01

Combustion Chamber

1

2

098324-02

098324-02

 

098324-02

098324-02

098324-02

Control Knob

1

3

097159-01

097159-01

 

097159-01

097159-01

097159-01

Piezo Ignitor

1

4

098271-05

098271-05

 

098271-05

098271-05

098271-05

Ignitor Cable

1

5

099974-03

099974-03

 

099974-02

099974-02

099974-01

Control Rod

1

6

063017

063017

 

100481-01

100481-01

063015

Limit Switch Bracket

1

7

M11084-26

M11084-26

 

——

——

M11084-26

Screw, #10-16 x 3/8"

6

 

——

——

 

M11084-26

M11084-26

——

Screw, #10-16 x 3/8"

5

8

099986-02

099986-02

 

099986-01

099986-01

099986-01

Wire Assembly

1

9

100000-01

100000-01

 

100000-01

100000-01

100000-01

Cotter Pin

1

10

231939

231939

 

231939

231939

231940

Limit Switch

1

11

M11084-38

M11084-38

 

M11084-38

M11084-38

——

Screw, #8-18 x 3/8"

3

 

——

——

 

——

——

M11084-38

Screw, #8-18 x 3/8"

2

12

099211-01

099211-01

 

099211-01

099211-01

099211-01

Screw, #10-16 x 2 1/4"

2

13

100207-02

100207-02

 

100207-02

100207-02

100207-02

Control Valve

1

14

098265-01

098265-01

 

098265-01

098265-01

098265-01

Elbow

1

15

098936-02

098936-02

 

098936-02

098936-02

098936-02

Thermocouple Interrupter

1

16

100028-02

100028-02

 

100028-02

100028-02

100028-02

Pilot Tubing

1

17

100307-01

100307-01

 

100307-01

100307-01

100307-01

Thermocouple

1

18

171176

171176

 

171176

171176

171176

Burner Tube

1

19

530988

530988

 

530988

530988

530988

Control Bracket

1

20

100309-01

100309-01

 

100309-01

100309-01

100309-01

Orifice Holder

1

21

180252

180252

 

530124

530124

100469-01

Orifice

1

22

100706-01

100706-01

 

100385-01

100385-01

100384-01

Burner Assembly

1

23

100310-01

100310-01

 

100310-01

100310-01

100310-01

Pilot Mounting Bracket

1

24

100308-02

100308-02

 

100308-02

100308-02

100308-02

Pilot (Includes 30 &31)

1

25

M12461-25

M12461-25

 

M12461-25

M12461-25

M12461-25

Screw, 10-32 x 1/4"

2

26

098249-01

098249-01

 

098249-01

098249-01

098249-01

Nut, M5 x 0.8

2

27

101342-03

101342-03

 

101342-02

101342-02

101342-01

Glass Panel Package

 

 

 

 

 

 

 

 

(Includes Retainer)

1

28

100772-01

100772-01

 

——

——

——

Radiant

5

 

——

——

 

100772-01

100772-01

——

Radiant

4

 

——

——

 

——

——

100772-01

Radiant

3

29

530192

530192

 

530192

530192

530192

Glass Spring

2

30

100468-01

100468-01

 

100468-01

100468-01

100468-01

Pilot Electrode

1

31

100465-01

100465-01

 

100465-01

100465-01

100465-01

Electrode Nut

1

 

 

 

 

 

 

 

 

 

100791

41

Image 41
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Contents Safety Information Safety Information Identification ProductInstalling Heater FeaturesLocal Codes UnpackingInstalling Heater Venting Heater Do not vent heater in any of the following ways see Figure Venting HeaterVenting Heater Proper Size Vent Supply. Follow all local codes Connecting to GAS SupplyQualified service person must connect heater to gas Gas Connection Checking GAS Connections Pressure Testing Gas Supply Piping SystemLocation of Radiants Installing RadiantsFor Radiant Models Only Installing Glass PanelInserting Glass into Lower Retaining Channel AIR for Combustion and Ventilation Ventilation AIR forDetermining FRESH-AIR Flow for Heater Location Draft Hood Spillage TestLeases poisonous carbon monoxide gas into your home 18 to make sure fresh air ventilation is adequate Confined area has an air volume of less than 50 cubicOperating Heater For Your Safety Read Before LightingViewing Pilot Blower Operation Manual Lighting ProcedureTo Turn OFF GAS to Appliance Shutting Off HeaterBurner Flame Pattern Inspecting Pilot and Burner FlamePilot Flame Pattern Flame Maintenance CleaningObserved Possible Problem Cause Remedy Trouble ShootingTROUBLE- Shooting Cleaning and MainteSee Changing Burner Orifice, Lighting Instructions Top Ing statement atRemoving Control Valve and Burner Tube Service ProceduresRemoving Burner Diagram WiringBlower Changing Burner OrificeService Hints Technical Service35,000 BTU/Hr 50,000 BTU/Hr ModelParts Under Warranty Ordering ReplacementParts Not Under Warranty PartsBlower KIT Part Number GA6010 AccessoriesBlower Assembly Illustrated Parts ListIllustrated Parts List Cabinet Assembly for Radiant Models Burner Assembly for Radiant Models Parts List Burner Assembly for Radiant Models 100791 100791 Limited Warranty GVR/GVC Vented Propane GAS Heaters Warranty Information